Error Indicators and Warning Messages
Warning messages and indicators let you know what the problem is when a projector error occurs.
When an error occurs, wait until the fan stops before unplugging the AC power cord. If you unplug the 
AC power cord while the fan is still operating, an error may occur when you plug the AC power cord 
back in.
Indicator/Error Message
Description and Required Action
POWER
: Green steady
The projector’s internal temperature is very high. Press the [ESC] key to 
clear the warning message and perform the following steps.
 Check for any blocking of the projector’s intake vents and exhaust 
vents, and make sure that there is sufficient space around the 
projector. See 
Setup Precautions” in the “User’s Guide (Basic 
Operations)”.
 If there is dust accumulated around the intake vents and/or exhaust 
vents, turn off the projector and remove it. See 
Projector” (page 36).
TEMP
: –
LIGHT
: –
Message
: Internal temperature is too 
high. Check projector air 
vents for blockage.
POWER
: Amber flashing  
Amber steady
Power has turned off automatically due to internal overheating. Perform 
the following steps.
 Check for any blocking of the projector’s intake vents and exhaust 
vents, and make sure that there is sufficient space around the 
projector. See 
Setup Precautions” in the “User’s Guide (Basic 
Operations)”.
 If there is dust accumulated around the intake vents and/or exhaust 
vents, remove it. See 
If there is no problem with the projector’s vents, confirm that the POWER/
STANDBY indicator is lit amber (without flashing), and then turn power 
back on again. If the error occurs again when you turn power back on, 
contact your retailer or nearest authorized CASIO Service Center.
TEMP
: –
LIGHT
: –
Message
: Internal temperature is too 
high. The projector will 
turn off.
POWER
: Amber flashing  
Red steady
Power has turned off automatically due to internal overheating. This 
causes a dialog box containing the text in the next item below to appear 
the next time you turn on the projector. Follow the steps that are 
provided.
TEMP
: Red flashing 
(0.5-second interval)
LIGHT
: –
Message
: –
POWER
: Green steady
The last time you were using the projector, power turned off 
automatically due to internal overheating. Press the [ESC] key to 
clear the warning message and perform the following steps.
 Check for any blocking of the projector’s intake vents and exhaust 
vents, and make sure that there is sufficient space around the 
projector. See 
Setup Precautions” in the “User’s Guide (Basic 
Operations)”.
 If there is dust accumulated around the intake vents and/or exhaust 
vents, turn off the projector and remove it. See 
Projector” (page 36).
 Disconnect the power cord from the projector and wait for all of the 
projector’s indicators to go out. Next, reconnect the power cord and 
turn the projector back on. If the error occurs again when you turn 
power back on, contact your retailer or nearest authorized CASIO 
Service Center.
TEMP
: –
LIGHT
: –
Message
: The projector has a 
history of turning off due 
to high temperature. 
Check air vents for 
blockage.