Table 11   Hardware Specifications
Dimensions (W x D x H)  PLA-400/400 v2/402 
112 (L) mm x 106 (D) mm x 28.5 (H) mm
PLA-470 
162 (L) mm x 118 (D) mm x 40 (H) mm
Power Input
100 - 240 VAC, 50/60 Hz, 0.12 A
Ethernet Port
Auto-negotiating: 10 Mbps or 100 Mbps in either half-duplex or full-duplex 
mode.
Auto-crossover: Use either crossover or straight-through Ethernet cables.
RESET
Pressing this button in for less than 3 seconds resets the device to factory 
default settings. Network Name becomes HomePlugAV.
Pressing this button in for more than 10 seconds resets the firmware to the 
previous version.
ENCRYPT
Pressing this button in for less than 3 seconds begins the connection setup 
process.
Pressing this button in for more than 10 seconds resets the network name 
to a random value.
Operation Environment
Temperature: 0º C ~ 45º C
Humidity: 5% ~ 95% Noncondensing
Storage Environment
Temperature: -10º C ~ 70º C
Humidity: 10% ~ 85% Noncondensing
Cabling Type
PLA-400/400 v2/402/470
1 x Power Cord 
PLA-400/400 v2/402
1 x LAN UTP Category 5 or Better
PLA-402 
1 x Coaxial Cable 
PLA-470 
4 x LAN UTP Category 5 or Better 
Network Interface
PLA-400/400 v2/401/402/470
1 x 200 Mbps Powerline port compliant with HomePlug AV standard
PLA-400/400 v2/401/402
1 x 10/100M BASE-T Ethernet port with Auto MDI/MDIX
PLA-470 
4 x 10/100 M Base-T Ethernet Ports with Auto MDI/MDIX
PLA-402 
1 x Coaxial Cable Port