INSTEON 2475d User Manual

Page of 13
                                                                                                                                  Page 5 of 13                                                                                 Rev: 1/21/2014 7:17 AM 
6) 
Referring to the diagram at right and the table below, use the 
included wire nuts to connect the fixture’s Line, Load, Neutral 
and Ground wires to In-LineLinc’s corresponding wires. 
7) 
Enable power to the switch from the circuit breaker or fuse 
panel. 
8) 
Use In-LineLinc’s On and Off buttons to test that In-LineLinc is installed properly. 
The load will turn on and off. 
9) 
Adjust and set the local on-level and ramp rate for the connected load. 
10) 
Link In-LineLinc to an INSTEON controller. 
11) 
Gently place In-LineLinc into the junction box, making sure nothing could accidentally press the 
buttons on its face. 
12) 
Reinstall the fixture. 
 
Note: the Neutral wire will not normally be connected to the switch you are replacing. If there is no 
Neutral wire in the box, consult an electrician or call the INSTEON Support Line at 1-800-762-7845. 
 
Using In-LineLinc Dimmer 
Button Functions 
Button 
Tap 
Double-Tap 
Press and Hold 
ON 
Ramp to on-level 
Fast on 
Brighten 
OFF 
Ramp to off 
Fast off 
Dim 
Set 
Set the default 
on-level 
Sets the default 
ramp rate 
Starts linking 
mode 
 
An Important Note About INSTEON Networks 
Split Single-Phase vs. 3-Phase Installation 
For the best INSTEON network performance, be sure you have properly installed at least two Access 
Points (#2443) or other 
. INSTEON has only been officially tested in a split 
single-phase residential environment, but has been known to work in many 3-phase systems with three 
dual-band products installed (one on each phase). However, due to the potential complexity of its 
troubleshooting, the INSTEON Support Line is unable to support INSTEON in 3-phase environments. 
 
In-LineLinc Wire 
Wall Box Wires 
Bare copper 
Ground 
(commonly bare copper, green 
wire or green screw) 
White 
Neutral 
(commonly white wire bundle) 
Red 
Load  
(light, fan, etc.) 
Black 
Line 
(100 - 277V to Ground)