IronPort Systems ES-1528 User Manual

Page of 170
Chapter 19 RMON-Lite
ES-1528 User’s Guide
124
19.4.3  RMON History Statistics : Overview  
Use the RMON History Statistics : Overview screen to view the results of statistical 
sampling on the ports. Select [2] History Statistics from the RMON MIB Table: drop down 
listbox in the RMON-Lite screen to view the screen as shown.
Figure 76   RMON History Statistics : Overview.
The following table describes the labels in this screen.   
BucketRequested This field displays the number of samplings the Owner of the entry requests.
Interval 
Enter the time (in seconds) between data samplings.
Owner
Enter a descriptive name of the application that creates this entry. You can use 1-64 
printable characters. Spaces are not allowed.
Status
Select Enable/Disable to activate or deactivate statistical sampling on the port.
Apply
Click this to save the settings on the switch. 
History Control 
Overview
Click this to go back to the RMON History Control : Overview screen.
Table 56   RMON History Control : Modify (continued)
LABEL
DESCRIPTION
Table 57   RMON History Statistics : Overview
LABEL
DESCRIPTION
RMON MIB 
Table:
Use this drop down list box to select the MIB table you want to view. Click Apply to 
refresh the screen to the selected MIB table view. 
Refresh
Click this to update all the fields in the RMON History Statistics : Overview screen.
History Control 
Index
This field displays the configuration index number. Click on the index number to view 
the details for this entry.
Data Source
This is the port of the switch polled for data. 
Bucket Granted This field displays the number of data samplings the probe allows to store. 
Interval 
This field displays the time between data samplings in seconds.
Owner
This field displays the creator of this entry.