INSTEON 2476dbr User Manual

Page of 21
                                                                                                                                  Page 12 of 21                                                                                 Rev: 1/21/2014 7:15 AM 
 
1)  Press and hold the controller Set or scene button until it beeps and/or LED blinks (about 3 seconds) 
Controller LED will blink 
2)  Press and hold the controller Set or scene button until it beeps and/or LED blinks again 
Controller LED will continue blinking 
You will have 4 minutes to complete the next step before unlinking mode times out
 
3)  Press and hold SwitchLinc Set button until it double-beeps 
SwitchLinc status LED will flash once, then turn on solid 
4)  Confirm that unlinking was successful by tapping the controller button on and off 
The load connected to SwitchLinc will no longer respond 
 
Scenes 
INSTEON scenes let you activate dramatic room ambiences with multiple lights and appliances. For 
example, you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others 
off, all with the tap of a button on a controller. 
INSTEON scenes are very easy to set up: just link more than one responder to the same On/Off or scene 
button on a controller. Then, when you press any of the linked buttons on the controller, all of the 
INSTEON devices linked in the scene will respond as a group. 
To set up an INSTEON scene, you can individually link each device to a controller. Or save time and 
create multiple links at once. 
 
Power Restore
 
SwitchLinc stores all of its scenes, properties, etc. in its internal non-volatile memory so all settings are 
retained after a power outage. Upon power being restored, SwitchLinc will return its connected load(s) 
and all LEDs to their states prior to power outage. 
 
 
Using SwitchLinc in an X10 Network 
Like most INSTEON devices, SwitchLinc X10-ready, meaning it can both send and respond to X10 
commands. However, SwitchLinc does not ship with an X10 address, so you must set one up when first 
installing SwitchLinc or after performing a factory reset.
 
Add an X10 Address  
1)  Press and hold SwitchLinc Set button until it beeps (about 3 seconds) 
SwitchLinc status LED will blink 
You will have 4 minutes to complete the next step before linking mode times out 
2)  Using an X10 controller, send the X10 address you want to assign to SwitchLinc followed by the ON 
command three times 
For example, to assign the address A1, you would send A1-ON-A1-ON-A1-ON 
3)  Once SwitchLinc Dimmer has received the sequence, it will exit linking mode 
SwitchLinc will double-beep 
Remove an X10 Address 
If you are no longer going to utilize an X10 address associated with SwitchLinc, it is very important that 
you remove its X10 address. Otherwise, SwitchLinc will still listen for X10 commands (somewhat 
hindering INSTEON reception) and may respond to spurious X10 “noise.” Furthermore, SwitchLinc will 
transmit an X10 address and command every time the button is tapped. 
1)  Press and hold SwitchLinc Set button until it beeps (about 3 seconds)