INSTEON 2732-232 User Manual

Page of 27
                                                                 Page 20 of 27                                            Rev: 1/21/2014 8:36 AM 
     
 
2)  Press Program to exit calibration mode 
Advanced 2-Stage Heating or Cooling Systems 
INSTEON Wireless Thermostat does not have the ability to operate first or second stages of Heat or Cool 
directly but can instruct INSTEON Thermostat to operate the HVAC. First and second stage of Heat or 
Cool engages under the following conditions when INSTEON Thermostat is connected to the HVAC: 
 
• 
INSTEON Thermostat setpoint is set at 5
°(F or C)
 or more below ambient in Cool mode and 5
°
(F 
or C) or more above ambient in Heat mode 
Heat mode setpoint is 80°, ambient is 72° = first and second stage engaged 
Cool mode setpoint is 78°, ambient is 84° = first and second stage engaged 
 
• 
INSTEON Thermostat has been active in Heat or Cool for longer than 10 minutes and did not 
reach setpoint 
Heat mode ran for 10 minutes and did not reach setpoint = second stage engaged 
Cool mode ran for 10 minutes and did not reach setpoint = second stage engaged 
 
Note: It is possible for INSTEON Thermostat to occasionally engage and disengage second stage during 
a single heating or cooling cycle as variables are met. 
 
Factory Reset 
If you want to reset INSTEON Wireless Thermostat to its factory default settings, follow instructions 
below. 
Note: If you choose to reset INSTEON Wireless Thermostat to its factory default settings, it is important 
that you remove scene memberships from all controllers. Otherwise, controllers will retry commands 
repetitively, creating network delays. Follow the instructions in 
Removing INSTEON Wireless Thermostat 
as an INSTEON Responder above for each scene controller of which INSTEON Wireless Thermostat is a 
member. 
 
Factory reset changes: 
•  INSTEON is reset (all scene memberships are removed) 
•  Day/time is changed to 12:00PM 
•  Programming times, temperatures and other settings are reset to their default values 
 
Factory reset does not change: 
•  Temperature offset 
•  Humidity offset 
 
Factory Reset  
1)  Open INSTEON Wireless Thermostat and remove a battery 
2)  Wait 10 seconds 
3)  While pressing and holding the Set button, reinsert the removed battery. Do not let go of Set button. 
Device will blink all segments and emit a long beep for about 10 seconds