2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM 
Ramp Rate Presets 
“Instant” 
0.5 seconds  
(factory default) 
2 seconds 
5 seconds 
 
9)  Test by turning off and then back on via the local switch 
Light will ramp off and back on at the new local ramp rate
 
 
Resume Dim 
When resume dim is enabled, each time you turn on Micro module it will go to the previously used dim 
level. By default, Micro module will come on at 100% brightness, but to change the desired level, simply 
follow the instructions below. The next time you turn Micro module off and on again, it will return to the 
last used dim level. 
1)  Press and hold set button until it beeps 
LED will start blinking green
 
2)  Press and hold set button until it beeps a second time 
LED will start blinking red 
3)  Press and hold set button until it beeps a third time 
LED will start blinking green 
4)  Press and hold set button until it beeps a fourth time 
LED will start blinking red 
5)  Slowly tap set button three times 
LED will start double-blinking red 
6)  Press and hold set button until it double-beeps 
LED will stop blinking 
7)  Test by turning off and then back on via the local switch 
Light will ramp off and back on to resume dim level.
 
 
Change LED Brightness (or turn it off) 
Default = 50% brightness level 
 
1)  Press and hold set button until it beeps 
 
 
LED will start blinking green  
2)  Press and hold set button until it beeps a second time 
 
 
LED will start blinking red
 
3)  Press and hold set button until it beeps a third time 
 
 
LED will start blinking green
 
4)  Tap set button once 
 
 
LED will start double-blinking green
 
5)  Press and hold set button until it beeps 
LED will turn green (at brightness of connected load)
 
6)  Press and hold Micro module on/off buttons to brighten or dim LED to desired brightness 
7)  Tap set button 
 
 
Micro Module will double-beep and return to ready mode