Micro module will beep and LED will stop blinking  
6)  Test by tapping the switch wired into Micro module on and off  
None of the former responders will respond  
 
Factory Reset 
All settings and scenes will be erased and return to factory default settings.  
1)  Press and hold Micro module set button until it beeps 
 
 
LED will start blinking green  
2)  Press and hold Micro module set button until it beeps a second time 
 
 
LED will start blinking red
 
3)  Press and hold Micro module set button until it beeps a third time 
 
 
LED will start blinking green
 
4)  Slowly tap Micro module set button 3 times 
LED will start double-blinking green
 
5)  Press and hold Micro module set button. Do not let go. 
Micro module will begin to emit a long beep
 
6)  After beep stops, release Micro module set button 
After a few seconds, the LED will flash white 
Micro module will double-beep and the load will turn on 
 
X10 Setup 
Micro module ships with no X10 address assigned.  
Add X10 Address 
1)  Press and hold set button until it beeps  
LED will start blinking green
 
2)  Send the X10 address 3 times (with or without commands) 
Example: A1-AON-A1-AON-A1-AON or A1-A1-A1-AON 
Micro module will double-beep and LED will stop blinking 
 
3)  Test by sending X10 on and off commands 
Load will turn on and off 
 
Remove X10 Address 
1)  Press and hold set button until it beeps  
LED will start blinking green
 
2)  Press and hold set button until it beeps a second time 
LED will start blinking red
 
3)  Send the X10 address 3 times (with or without commands) 
Example: A1-AOFF-A1-AOFF-A1-AOFF or A1-A1-A1-AOFF 
Micro module will double-beep and LED will stop blinking 
 
4)  Test by sending X10 on and off commands  
Micro module will not respond