Intel SSDSC2BB160G401 User Manual

Page of 33
 
Intel® Solid-State Drive DC S3500 
December 2013 
Product Specification 
328860-002US   
21
 
5.4 
SMART Command Set 
Intel SSD DC S3500 supports the SMART command set, which consists of: 
− 
SMART READ DATA 
− 
SMART READ ATTRIBUTE THRESHOLDS 
− 
SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE 
− 
SMART SAVE ATTRIBUTE VALUES 
− 
SMART EXECUTE OFF-LINE IMMEDIATE 
− 
SMART READ LOG SECTOR 
− 
SMART WRITE LOG SECTOR 
− 
SMART ENABLE OPERATIONS 
− 
SMART DISABLE OPERATIONS 
− 
SMART RETURN STATUS 
− 
SMART ENABLE/DISABLE AUTOMATIC OFFLINE 
5.4.1 
SMART Attributes 
Table 18 lists the SMART attributes supported by the Intel SSD DC S3500 and the 
corresponding status flags and threshold settings. 
Table 18. 
SMART Attributes  
ID 
  Attribute 
Status Flags 
Threshold 
SP 
EC 
ER 
PE 
OC  PW 
05h 
Re-allocated Sector Count 
 
Raw value: shows the number of retired blocks since 
leaving the factory (grown defect count). 
    Normalized value: beginning at 100, shows the percent 
remaining of allowable grown defect count. 
0 (none) 
09h 
Power-On Hours Count 
 
Raw value: reports power-on time, cumulative over the life 
of the SSD, integer number in hour time units. 
     Normalized value: always 100. 
0 (none) 
0Ch 
Power Cycle Count 
Raw value: reports the cumulative number of power cycle 
events over the life of the device. 
    Normalized value: always 100. 
0 (none) 
AAh 
Available Reserved Space (See Attribute E8) 
10 
ABh 
Program Fail Count 
Raw value: shows total count of program fails. 
Normalized value: beginning at 100, shows the percent 
remaining of allowable program fails. 
0 (none) 
ACh 
Erase Fail Count 
Raw value: shows total count of erase fails. 
Normalized value: beginning at 100, shows the percent 
remaining of allowable erase fails. 
0 (none) 
AEh 
Unexpected Power Loss 
Also known as “Power-off Retract Count” per magnet-
ic-drive terminology. 
Raw value: reports number of unclean shutdowns, cumu-
lative over the life of the SSD. 
An “unclean shutdown” is the removal of power without 
STANDBY IMMEDIATE as the last command (regardless of 
PLI activity using capacitor power). 
Normalized value: always 100. 
0 (none) 
AFh 
Power Loss Protection Failure 
Last test result as microseconds to discharge cap, saturates 
at max value. Also logs minutes since last test and lifetime 
number of tests. 
    Raw value
    Bytes 0-1: Last test result as microseconds to discharge             
cap, saturates at max value. Test result expected in range 
10