Navman 11 User Manual

Page of 90
27
MN002000A © 2004 Navman NZ Ltd. All rights reserved. Proprietary information and specifications subject to change without notice.
Message ID: 1130
Rate: Variable
Message Length: 21 words
Word No.
Name
Type
Units
Range
1-4
Message header
5
Header checksum
6-7
Set time (Note 1)
UDI
10 ms ticks
0 to 4 294 967 295
8
Sequence number (Note 2)
I
0 to 32 767
Port 1 communication parameters (9.0-11)
9
Port 1 character width
Bit
0 = 7 bits
1 = 8 bits
10
Port 1 stop bits
Bit
0 = 1
1 = 2
11
Port 1 parity
Bit
0 = no parity
1 = odd parity
2 = even parity
12
Port 1 bps rate (Note 3)
Bit
0 = custom
1 = 300
2 = 600
3 = 1200
4 = 2400
5 = 4800
6 = 9600
7 = 19 200
8 = 38 400
9 = 57 600
10 = 76 800
11 = 115 200
13
Port 1 pre-scale (Note 3)
UI
0 to 255
14
Port 1 post-scale (Note 3)
UI
0 to 7
Table 3-17 (1 of 2) Message 1130 (serial port communication parameters in use) 
3.5.1.13 Message 1130 (serial port communication 
parameters in use). 
This message contains the communication 
parameters for the receiver’s two serial ports. 
The contents of the ‘serial port communication 
parameters in use’ message are described in 
Table 3-17.