Use switches 3 and 4 of the four-position switch at location U35 to control 
the operation of the EEPROM. The Restore Factory Configuration switch 
(switch 4) causes the VXI-MXI-2 to boot off the factory-configured half 
instead of the user-modified settings. This is useful in the event that the 
user-configured half of the EEPROM becomes corrupted in such a way that 
the VXI-MXI-2 boots to an unusable state.
The Change Factory Configuration switch (switch 3 of U35) lets you 
change the factory-default configuration settings by permitting writes to the 
factory settings section of the EEPROM. This switch serves as a safety 
measure and should not be needed under normal circumstances. When this 
switch is off (its default setting) the factory configuration of the EEPROM 
is protected, so any writes to the factory area will be ignored. The factory 
area is protected regardless of the setting of switch 4 of U35.