Konica Minolta micropress release 6 User Manual
51
Edit Uncalibrated Target Dialog
Calibration sets must be made for each virtual printer
even if the set is identical. Tone Curves are available
to all devices.
even if the set is identical. Tone Curves are available
to all devices.
For both calibration sets and Tone
Curves, increasing percentage increases light-
ness. For calibration sets, another curve may be
required for best results as frequency or dot
shape is changed. Create the set by reading a
target generated at those settings.
Item
Description
Profile
ICC Output Profile associated with the device using the calibration set. Usually, leave the
profile selected.
profile selected.
Resolution
Resolution (horizontal and vertical) associated with the device using the calibration set.
Dot Shape
Dot shape for the calibration set.
Screen Freq:
Screen frequency range for the calibration set.
Exposure
Not used.
Use for Pos & Neg
Always select.
Name
Name of calibration set.
Channel
Sets color appropriate for the data. Monochrome printers have one channel.
Add
Pastes data from a channel into another.
Copy
Copies data from a channel.
Delete
Deletes data from a channel.
Measurements as
Depending on Device, Color Space, or Negative Media, select “Positive % dot,” “%Dot,”
or L*.
or L*.
Negative Media
Select if you are measuring from negative output.
Force solid colors
Forces maximum density job colors to be printed using the maximum colorant available
regardless of calibration set limits. Exact colorimetric match not always possible.
regardless of calibration set limits. Exact colorimetric match not always possible.
Percentage boxes
Contains values for each percentage. For calibration sets, enter the data obtained from the
Print Calibration procedure into the Calibration Manager (X-Rite step numbers are printed
on the target for convenience). Each value you enter (0—100) must be equal to or greater
than the preceding value.
Print Calibration procedure into the Calibration Manager (X-Rite step numbers are printed
on the target for convenience). Each value you enter (0—100) must be equal to or greater
than the preceding value.
Smooth
Reduces abrupt transitions in the curve.
Extrapolate
When percentage values are missing or if data expressed as a percentage at 50%, click
Extrapolate to calculate the remaining values. Click Clear before entering data to enable
Extrapolate.
Extrapolate to calculate the remaining values. Click Clear before entering data to enable
Extrapolate.
Clear
Empties the percentage value boxes. Click before entering data to enable Extrapolate.
Reset
Resets all data to default configuration.
Import
Imports data from a file rather than typing numbers into the boxes.
OK
Saves and exits.
Cancel
Exits without saving.