John Deere ac-1500eh User Manual

Page of 60
John Deere Operator's Manual   
 
 
 
 
 
 
 
15
INSTALLATION & PREPARATION
UNLOADER:
Standard Models:
 
The unloader has been preset at the factory. 
Steam Option Models:
 
The  unloader  has  an  adjustment  knob  which  has  a  minimum/maximum 
setting. Move the unloader clockwise to the maximum setting for Cold/Hot 
water  operation.    Move  counterclockwise  to  minimum  setting  for  Steam 
operation.
HEAT DUMP VALVE:
To ensure the water temperature does not exceed acceptable levels, never allow 
the pressure washer to operate in the bypass mode (with the unit running and 
the trigger closed) for more than three minutes.
A heat dump valve has been added to this unit to protect the pump. This valve 
will open and release water if the water temperature in the pump has exceeded  
140° F.  This will allow fresh, cool water to enter the system, therefore preventing 
premature failure of pump packings.  
PRE-START INSPECTION PROCEDURES:
Before starting the unit, perform the following procedures:
1.  Inspect the electrical cords for cuts.  If a cut is found, DO NOT TOUCH OR 
USE CORD!  Replace cord before starting unit. 
2.  Check the oil level in the pump.
3.  Inspect the water inlet strainer.  Clean or replace if necessary.  See "Water 
Supply", #2, pg 14.
4.  Check all hose connections to ensure they are securely tightened.
5.  Inspect for system water leaks, oil leaks and fuel leaks.  If a fuel leak is 
found, DO NOT START UNIT!  See "Risk of Explosion or Fire", pg. 5.  Be 
sure that all damaged parts are replaced and that the mechanical problems 
are corrected prior to operation of the unit.  If you require service, contact 
Customer Service.
6.  Inspect high pressure hoses for kinking, cuts and leaks.  If a cut or leak 
is found, DO NOT USE HOSE!  Replace hose before starting unit.  See 
"Risk of Injection or Severe Cutting Injury", pg. 7.  Be sure that all damaged 
parts are replaced and that the mechanical problems are corrected prior to 
operation of the unit.  If you require service, contact Customer Service.
 
 
 
 
UNLOADER VALVE