TROUBLESHOOTING
SYMPTOM 
 
 
 
PROBABLE CAUSE 
 
 
REMEDY 
Pump motor will not run.  
 
Circuit overload. 
 
 
Check wall breaker or fuse. 
 
 
 
 
 
 
 
 
 
 
 
GFCI tripped.   
 
 
Reset.  
 
 
 
 
 
 
 
 
 
 
 
Motor overload.  
 
 
Reset thermal overload button on  
 
 
 
 
 
 
 
 
 
 
pump motor or inside electrical    
 
 
 
 
 
 
 
 
 
 
control panel. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Auto Start/Stop Option in use.   
Point gun in a safe direction an   
 
 
 
 
 
 
 
 
 
 
squeeze trigger.  
No discharge at nozzle when   
Inadequate water supply. 
 
Ensure hose is 3/4" diameter and 
trigger mechanism is squeezed.  
 
 
 
 
 
incoming water supply is turned on. 
 
 
 
 
 
 
Low or fluctuating pressure. 
 
Kink in water inlet hose.  
 
Remove kink. 
  
 
 
 
 
 
Kink in high pressure discharge hose.  Replace kinked high pressure hose. 
 
 
 
 
 
 
Water inlet screen obstructed.   
Remove screen, clean or replace. 
 
 
 
 
 
 
 
Pump sucking air.  (Prime eliminated)  Tighten all water intake connections 
 
 
 
 
 
 
 
 
 
 
Eliminate leaks in intake line. 
 
 
 
 
 
 
Adjustable Grip on Dual Lance   
Turn grip 
counterclockwise to move   
 
 
 
 
 
is not in high pressure mode.   
to high pressure. 
 
 
 
 
 
 
 
 
 
 
 
Obstructed or worn spray nozzle. 
Remove, clean or replace. 
 
 
 
 
 
 
Damaged or obstructed valve assy. 
Remove, clean or replace. 
 
 
 
 
 
on pump. 
 
 
 
 
 
 
Pump packings worn.   
 
Replace packings. 
 
 
 
 
 
 
Unloader/Bypass valve not operating 
Repair or replace. 
 
 
 
 
 
correctly. 
 
 
 
 
 
 
Scale build-up in heat exchanger coil.  Descale coil. 
Water is leaking from Heat DumpValve.  Water inlet temperature is too high. 
Incoming water temperature must be  
 
 
 
 
 
 
 
 
 
 
less than 125°. 
 
 
 
 
 
 
Water temperature is too high.   
Do not allow unit to operate in    
 
 
 
 
 
 
 
 
 
 
bypass mode (with the trigger gun  
 
 
 
 
 
 
 
 
 
 
closed) for more than three minutes.   
 
 
 
 
 
 
Defective valve.  
 
 
Replace. 
Oil appears milky or foamy. 
 
Water in oil. 
 
 
 
Change pump oil.  Fill to proper   
 
 
 
 
 
 
 
 
 
 
level. 
Oil leaking from unit. 
 
 
Worn seals or o-rings.   
 
Contact Customer Service. 
Detergent will not siphon . 
 
Detergent strainer is not completely 
Check, submerge if necessary. 
 
 
 
 
 
submerged in detergent solution. 
 
 
 
 
 
 
Detergent strainer obstructed.   
Inspect, clean or replace.  
 
 
 
 
 
 
Detergent hose cut, obstructed or 
Inspect, clean or replace. 
 
 
 
 
 
kinked. 
 
 
 
 
 
 
Detergent adjusting knob turned to  
Open adjusting knob.  Refer to  
 
 
 
 
 
closed position.  
 
 
"Cleaning with Detergents"  pg. 18.