U-Line CLR2060 User Manual

Page of 44
37
Problem
Possible Cause
Remedy
Unit runs but
Scale and mineral 
Clean unit. See  
produces very
buildup in unit.
MAINTENANCE.
little ice.
Inadequate airflow at 
Remove items blocking 
(continued)
the front of the unit.
airflow.
Ice is slow to 
Ice-making system 
Run unit through 
release or does 
is dirty.
automatic clean cycle. 
not release from 
See MAINTENANCE.
the evaporator.
Unit is not level.
See LEVELING THE 
UNIT.
Low air temperature 
Surrounding air 
around unit.
temperature must be 
at least 50°F (10°C).
Poor ice quality.
Poor incoming water 
Consult a qualified 
(soft or unclear)
quality.
plumber to test the 
water quality and 
recommend appropriate 
treatment.
Ice-making system is 
Run unit through 
dirty.
automatic clean cycle. 
See MAINTENANCE.
Unit produces 
Low water level.
Check to see that 
shallow or 
overflow tube is fully 
incomplete cubes, 
seated.
or the ice fill 
pattern on the 
Hot incoming water.
Connect the unit to a 
evaporator is 
cold water supply. 
incomplete.
See INSTALLATION.
Incorrect incoming 
Water pressure must 
water pressure.
be 20-120 psi.
Unit is not level.
See LEVELING THE 
UNIT.
Body_UM.qxd  12/17/04  9:16 AM  Page 37