Removing rotating 
brush & belt 
L
,
M
7
Lift the metal belt guard ¯ out
of the floor nozzle and put it
safely to one side L.
8
Slide the belt past the end of the
motor drive shaft ˘. If the belt
has broken, remove all pieces
and clean the drive shaft.
9
Lift the rotating brush      equally
at both ends to slide it free of
the floor nozzle M. Holding the
ends of the brush, check it
rotates freely or not, if not, it
must be replaced. Call our
Helpline for replacement parts
or belts.
Re-fitting rotating 
brush & belt 
N
10
Hook the belt      over the the
drive shaft (the belt must be slid
sideways past the end of the
drive shaft). Note: The belt guard
must have been removed first,
see point 7 above.
11
Refit the belt guard, ensuring it
is correctly located. Press down
fully.
12
Pass the rotary brush through
the belt, ensuring the correct
end is located against the belt
N
.
13
Pull the brush forward (against
the pull of the belt) and locate
the square ends      of the brush
into location slots in the floor
nozzle N. 
14
Rotate the brush by hand to
ensure the belt is running in the
centre of it’s location on the
brush.
Refitting the floor 
nozzle base cover 
O
15
Hook the base cover ˜ into the
front of the floor nozzle,
ensuring all four hooks are
engaged O.
16
Rotating the cover downwards
and rearwards, slowly close the
cover.
17
Tighten the three fixings, using a
screwdriver to turn the fixings a
quarter-of-a-turn to the lock
position.
Note: If the cover will not fully
close or fixings will not lock, lift
the cover slightly and rotate the
fixings until they are in the
correct position for closure.
18
Return the cleaner to the upright
position, re-fit the dust canister
and front cover. Connect to the
mains supply. Switch on to test.
HELPLINE
If you have any difficulty with
your appliance, do not hesitate
to call us.
We are more likely to be able
to help than the store from
where you bought it.
Please have the following
information ready to enable our
staff to deal with your query
quickly.
Name of the product
Model number as shown on the
underside of the appliance.
Serial number as shown on
underside of the appliance.
UK Helpline
0844 871 0949  
Replacement Parts 0844 873 0715  
Ireland Helpline
1800 409 119
WEBSITE
You may also contact us through
our website, or visit the site to
browse and purchase
appliances, spare parts and
accessories from the extensive
Morphy Richards range.
L
M
N
O
˘
¯
˜
FFoorr  ddeettaaiillss  ooff  ootthheerr  M
Moorrpphhyy  RRiicchhaarrddss  pprroodduuccttss,,  pplleeaassee  sseeee  oouurr  w
weebbssiittee::
73332 rev3  10/9/08  09:56  Page 7