Crestron CEN-COM Ethernet 
RS-232/422 
COM 
Module
 
Expand the Ethernet folder and double click on the CEN-COM. Double click on Port 
A for a detail view of the symbol (alternatively CTRL+D or drag and drop into 
Detail View). Assign the signal as shown after this paragraph.  
Detail View of the CEN-COM in SIMPL Windows’ Programming Manager 
 
All logic symbols necessary for the SIMPL Windows program must be added from 
the Symbol Library in the Programming Manager workspace. In this example, drag 
and drop one NOR symbol from the Conditional folder into the Logic folder in 
Program View. Expand the Logic folder and double click on the symbol icon for a 
detail view (alternatively CTRL+D or drag and drop into Detail View). Assign 
signals as shown on the next page.  
Detail View of the NOR (S-1)  in SIMPL Windows’ Programming Manager 
 
NOTE:  For a more descriptive symbol name, right mouse click on the symbol icon 
in the Logic folder in Program View and select Edit Symbol Comment 
(alternatively, highlight the icon and depress Ctrl+R or Tab). Enter a new descriptive 
name in the “Enter Symbol Comment” dialog box and click OK.  
Operations Guide - DOC. 5719 
Ethernet RS-232/422 COM Module: CEN-COM  