Furuno 1834C-BB User Manual

Page of 233
5. AIS OPERATION 
 
5-6 
CPA
{
{
{
{
{
{
{
~
OFF
0.5nm
1nm
2nm
3nm
4nm
5nm
6nm
S
T
 
CPA window 
6.  Select a CPA limit desired from 0.5 nm, 1 nm, 2 nm, 3 nm, 5 nm and 6 nm with the 
Trackball
7.  Press the C: ENTER soft key.   
8. Choose TCPA. 
9.  Press the A: EDIT soft key to show the TCPA window. 
TCPA
{
{
{
{
{
{
{
~
30 seconds
1 minute
2 minutes
3 minutes
4 minutes
5 minutes
6 minutes
12 minutes
S
T
 
TCPA window 
10. Select a TCPA limit from 30 sec, 1 min, 2 min, 3 min, 4 min, 5 min, 6 min and 12 min. 
11. Press the C: ENTER soft key. 
12. Press the MENU key to close the menu. 
 
 
5.8 Proximity 
Alarm 
The proximity alarm alerts when there are AIS targets within the range you set. When an 
AIS target comes within the proximity alarm range, the message AIS TARGET COMES 
CLOSE appears. 
 
1. Press the MENU key followed by the ARP SETUP soft key. 
2.  Press the E: SYSTEM CONFIGURATION soft key. 
3.  Press the A: GENERAL SETUP soft key. 
4.  Press the C: AIS OPTION soft key to show the AIS OPTION menu. 
5.  Choose PROXIMITY ALARM and push the ENTER knob. 
6.  Enter proximity alarm range (0.01-24 nm) and press the C: ENTER soft key. 
7. Press the MENU key to close the menu.