Furuno 1834C-BB User Manual

Page of 233
8. MAINTENANCE, TROUBLESHOOTING 
 
8-13
8.10 Clearing Memories 
Your equipment has a memory for each of the plotter, radar and sounder sections. These 
memories can be cleared to restart operation with default settings. 
 
The following data are not cleared:   
 
Radar: Heading adjustment, timing adjustment, MBS level, tuning point, tuning indication 
(short, medium, long), video level, dead sector, antenna height, STC curve, antenna type, 
on time, tx time, Sounder: White marker, hue, signal level, TLL output, depth calibration, 
range. 
 
1. Press the MENU key to open the menu. 
2.  Press the E: SYSTEM CONFIGURATION soft key. 
3.  Press the C: SYSTEM SETUP soft key. 
4.  Press the B: TEST & CLEAR soft key. 
5.  Press the D: MEMORY CLEAR soft key. 
MEMORY
     CLEAR
PROCESSOR UNIT         NO
GPS SENSOR                  NO
NETWORK SOUNDER    NO
RETURN
E
EDIT
A
 
Memory clear menu 
6. Use the Trackball to choose the memory to clear. 
7.  Press the A: EDIT soft key.   
8. Use the Trackball to select YES, then press the C: ENTER soft key. One of the 
following displays appears depending on the selection made at step 6. 
ALL SETTNGS EXCEPT
SNDR ARE RESET TO
DEFAULT. ARE YOU SURE?
YES ... PUSH ENTER KNOB
NO  ... PUSH CLEAR KEY
BEGIN COLD START
TO CLEAR GPS
MEMORY. ARE YOU SURE?
  YES ... PUSH ENTER KNOB
  NO   ... PUSH CLEAR KEY
SOUNDER WILL BE 
SET TO DEFAULT. 
ARE YOU SURE?
YES ... PUSH ENTER KNOB
NO   ... PUSH CLEAR KEY
Processor Unit Clear              GPS Receiver Clear              Network Sounder Clear
 
Windows for clearing memory 
9. Push the ENTER knob to clear the memory selected. 
10. Press  the  MENU key to close the menu. 
11. Turn the power off and on again. 
 
Note: The message “SYSTEM HAS FAILED START UP TEST. PLEASE CONTACT A 
LOCAL FURUNO REPRESENTATIVE FOR REPAIR. PUSH ANY KEY TO CONTINUE.” 
may appear when powering on the processor unit immediately after clearing any memory. It 
is not an indication of malfunction. Press any key to continue operation.