Furuno 1834C-BB User Manual

Page of 233
2. RADAR OPERATION 
 
2-5
2.7 Range 
Scale 
The range setting determines the size of the area (in nautical miles) that will appear on your 
display. In addition, the range setting will also automatically adjust the range ring interval so 
that accurate range measurements may be made while operating on any range setting. 
 
The range, range ring interval and pulselength appear at the top left-hand corner of the 
display. 
 
Press the [RANGE (+ or -)] key to change the range scale. 
Range scales (nm, sm) 
Range  0.125  0.25  0.5  0.75 1 
1.5 2  3 4 6 8 12 16 24 36 48 64 72
Ring 
Interval 
0.0625 0.125 0.125
0.25 0.25 0.5 0.5 1  1  2  2  3  4  6  12  12  16  18
No. of 
Rings 
5  4  5  4 5 4 
5 5 5 4 5 5 5 
 
Range scales (km) 
Range 
0.25 0.5 
0.75
1 1.5 
2 3 4 6 8 12 16 24 36 48 64 72 
Ring 
Interval 
0.125 
0.25 
0.25
0.25 
0.5 
0.5 
1 1 2 2 3 4 6 12 12 16 18 
No. 
of 
Rings 
5 4 5 4 5 4 5 4 5 5 5 5 4 5 5 5 
Note 1: Maximum range depends on the network radar as shown below. 
Model 1824C-BB: 24 nm 
Model 1834C-BB: 36 nm 
Model 1934C-BB: 48 nm 
Model 1944C-BB: 64 nm 
Model 1954C-BB, 1964C-BB: 72 nm 
Note 2: You may choose which ranges to use from the RADAR RANGE SETUP menu. For 
details see paragraph 7.2.2. This function is not available with the GD-1920C-BB. 
 
 
2.8 Pulselength 
The pulselength in use is displayed at the upper left corner of the display. Appropriate 
pulselengths are preset to individual range scales. Therefore, you are not usually required 
to select them. If you are not satisfied with the current pulselength setting, however, it is 
possible to change it for the ranges shown below. Generally, select a longer pulse for 
longer detection range and shorter pulse for better range discrimination. 
 
1.5 nm, 1.5 sm, 3 km: Short pulse, medium pulse 
3 nm, 3 sm, 6 km: Medium pulse, long pulse 
 
1.  If not displayed, press the HIDE/SHOW key to show the radar soft keys. 
2.  Press the A: SIGNAL PROC. soft key.