2. RADAR OPERATION 
 
2-12
1.  If not displayed, press the HIDE/SHOW key to show the radar soft keys. 
2.  Press the A: SIGNAL PROC. soft key.   
Shown when radar 
source is the Model
18x4-BB/19x4-BB
series radar. Not
shown otherwise.
SIGNAL
PROCESS
359.9 ˚R
 11.70
nm
+
12/        
H-UP 
     3nm
LP
319. 9
°
M
RETURN
E
C
A
I.  REJ
 OFF
B
E. AVG
OFF
D
E. STR
OFF
PULSE
E
LONG
 
SIGNAL PROCESS soft keys 
3.  Press the A: I. REJ soft key successively to choose the interference rejection level 
desired; LOW, MED, HIGH or OFF. 
4.  Press the E: RETURN soft key to finish. 
 
The display shows IR L (Low), IR M (Medium) or IR H (High) when the interference rejector 
is on. 
 
 
2.15 Zoom 
The zoom feature allows you to double the size of the area selected with the “zoom 
square.” It is available on any range but is inoperative in true motion and when the display 
is shifted. 
 
2.15.1 Zooming radar targets 
1.  If not displayed, press the HIDE/SHOW key to show the radar soft keys. 
2. Use the Trackball to set the cursor where you want to zoom. 
3.  Press the E: ZOOM & D. BOX soft key to show ZOOM & D. BOX soft keys. 
4.  Press the A: ZOOM ON/OFF soft key to select ON. A hollow square, called the “zoom 
area,” appears on the display. 
5.  To release the cursor, press the B: CURSOR FLOAT soft key. (The hollow square 
changes to a dashed one.) To relocate the zoom circle, select location with the 
Trackball
, then press the B: CURSOR LOCK key. 