Fujitsu TX200 S6 VFY:T2006SF040DE S26361-F2567-L371 Data Sheet

Product codes
VFY:T2006SF040DE S26361-F2567-L371
Page of 9
Data Sheet
 Fujitsu PRIMERGY TX200 S6 Server 
Page 6 / 9
http://ts.fujitsu.com/Primergy
Server Management
Option
ServerView Integration for Tivoli TEC®, Tivoli NetView, HP NNM and HP Operations Manager
iRMC S2 Advanced Pack
Server Management notes
Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated 
Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H)
205 (306 ) x 584 x 444 mm
Rack (W x D x H)
482 x 570 x 220 mm
Dimension notes
Floorstand Width 306 mm with tilt protection; depth measured excludes handles on redundant PSU. Rack depth 
excludes handles of redundant PSU and rack front.
Mounting Depth Rack
596 mm
Height Unit Rack
5 U
Weight
up to 36,8 kg
Weight notes
Actual weight may vary depending on configuration
Rack integration kit
Rack integration kit as option
Environmental
Noise emission
Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm)
34 dB(A) (idle) /  36 dB(A) (operating)
Sound power (LWAd; 1B = 10dB)
5.2 B (idle) / 5.7 B (operating)
Noise notes / description
measured with standard fans and PSU
Operating ambient temperature
10 - 35C
Operating relative humidity
10 - 85 % (non condensing)
Operating environment
FTS 04230  Guideline for Data Center (installation locations)
Operating environment Link
http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Electrical values
Power supply configuration
1x standard, 1x hot-plug or 2x redundant
Max. output of single power supply
685 W
Standard power supply output
700 W (85% efficiency)
Hot-plug power supply output
800 W (92% efficiency)
Hot-plug power supply redundancy
Yes
Rated voltage range
100 V - 240 V
Rated frequency range
47 Hz - 63 Hz
Rated current max.
9.5 - 4.0A  
Rated current in basic configuration
1,3  0.6A
Active power (min. configuration)
111 W
Active power (max. configuration)
461 W
Apparent power (max. configuration)
490 VA
Heat emission
1659.6 kJ/h (1573.0 BTU/h)
Power Supply Notes
In case of using an UPS we recommend to select a 1500VA/1000 W type as a minimum, because high power peaks 
might be possible when switching over to battery!
The following Energy Star Familiy configuration options  use less energy and reduce greenhouse gas emissions: 
 TX200 S6 E-StarFam1
http://ts.fujitsu.com/products/standard_servers/e_efficient.html
Compliance
Germany
TÜV GS
Europe
CE Class A *
USA/Canada
CSAc/us
ULc/us
FCC Class A
Global
CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan
VCCI Class A + JIS 61000-3-2