Panasonic CU-RE9PKE-3 Operating Guide

Page of 32
26
 
 
INDOOR UNIT
OUTDOOR UNIT
Product Specification 
•  Standby power consumption ≤ 7.5W (when switched OFF by remote control, except under self-
protection control). 
•   Standard piping length: 5m.
•  Air filters are attached. 
 
  Model
     CS-RE9PKE-3
 
 CU-RE9PKE-3
     CS-RE12PKE-3
 
 CU-RE12PKE-3
     CS-RE15PKE-3
 
 CU-RE15PKE-3
COOL
HEAT
COOL
HEAT
COOL
HEAT
Single, 230V,50Hz Single, 230V,50Hz Single, 230V,50Hz
 Power/Current 
[kW]
0.700
0.820
1.010
1.120
1.260
1.385
[A]
3.30
3.80
4.70
5.20
6.00
6.30
 
  Refrigerant 
[kg]
0.770
0.860
0.920
  Cooling Capacity 
[kW]
2.50
3.50
4.20
 
 Heating Capacity 
[kW]
3.30
4.25
5.00
Noise Level 
JIS C 9612 
[<70 dB(A)]
[dB(A)]
   
42
42
42
42
44
46
Conditions 1m 
Distance 
Max. cooling/
heating 
operation 
47
48
48
50
49
51
Sound power 
level
[dB(A)]
   
58
58
58
58
60
62
63
64
64
66
65
67
 
 Air Circulation 
[m
3
/min.] 
12.5
11.1
12.5
12.5
13.7
14.5
 
kg
 Product Weight
[kg]
   
8.0
8.0
8.0
23
26
27
 
 Dimensions (H x W x D) 
[mm]
   
290×848×213
290×848×213
290×848×213
540×780×289
540×780×289
540×780×289
09 F568947-CR.indd   26