Registration of input signal data
• The data of 96 input signals can be registered.
• The signals supporting the installed input module are input and their data registered.
• The memories are numbered over 12 pages (A to L: 8 data items can be registered on each page),
and the data is registered in the unused memory with the lowest number.  If all the memories are used,
the data of the old signals is overwritten in sequence.
• The names of the registered data are automatically determined by the input signals and memory
numbers.
The input signal data must be registered because it is not registered on shipment of the projector.
Note
Renaming the registered signals
Registration of new data
When a new signal is supplied, press the “MENU” button on the remote control or operating section of the main
unit.  When its data has been registered, the MAIN MENU screen is displayed.
Press the “MENU” button.
The MAIN MENU screen will be displayed.
Select “SIGNAL LIST” with the 
and
buttons.
Note
MAIN MENU
         PICTURE
         POSITION
         ADVANCED MENU
         LANGUAGE
         OPTION
         TEST PATTERN
         SIGNAL LIST
         SECURITY
     :MENU SELECT
ENTER:SUB MENU
REGISTERED SIGNAL LIST
  A1:SVGA72-A1
RGB1
– – –
  A2:SVGA72-A2
RGB1
– – –
  A3:SVGA72-A3
RGB1
– – –
  A4:SVGA72-A4
RGB1
– – –
  A5:SVGA72-A5
RGB1
– – –
  A6:SVGA72-A6
RGB1
– – –
  A7:SVGA72-A7
RGB1
– – –
  A8:SVGA72-A8
RGB1
– – –
            :SELECT    ENTER:DETAILS    STD:DELETE
REGISTERED SIGNAL STATUS
  NAME:
SVGA72-A2
  MEMORY NO:
A2
  S.S.NO:
– – –
  INPUT NO:
RGB1
  fH:
  48.08kHz
  fV:
  72.17Hz
  SYNC. STATE:
H(POS)
V(POS)
ENTER:CHANGE NANE
Press the “ENTER” button.
The REGISTERED SIGNAL LIST screen will be
displayed.  The memories extend over 12 pages (A
to L with 8 data items each, giving a total of 96
memories).
Select the signal whose details are to
be displayed with the  
, ,  and 
buttons.
Press the “ENTER” button.
The REGISTERED SIGNAL STATUS screen will
be displayed.
• The data items including the input signal
name, memory number, signal selector
input number, input terminal, frequency
and sync signal are automatically
identified and displayed.
• When the “MENU” button is pressed, the
REGISTERED SIGNAL LIST screen is
restored.