www.opticis.com
EMC Test Data
1) EMI: Meet FCC class A (ICES-003) and CE class A
STANDARDS
CONDITIONS
EN 55 022 (CISPR22)
FCC; PART 15 SUBPART B
FCC; PART 15 SUBPART B
CE (Conducted Emission) &
RE (Radiated Emission)
Meet Class A
EN 61000-3-2 (IEC 61000-3-2)
Harmonics
Meet Class A
EN 61000-3-3 (IEC 61000-3-3)
Flickers
Meet Class A
2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents
STANDARDS
CONDITIONS
EN 61 000-4-2:1995
Electrostatic Discharge Immunity
(Air: 8kv, Contact: 4kv)
Meet Criterion B
EN 61 000-4-3:1996
Radiated RF E-Field (80~1000 MHz)
3V/m (AM 80%, 1kHz)
Meet Criterion A
EN 61 000-4-4:1995
Fast Transients (5kHz, 60Seconds)
Meet Criterion B
EN 61 000-4-5:1995
Surge Transients
Meet Criterion B
EN 61 000-4-6:1996
Conducted Susceptibility (CS)
Radiated Susceptibility (RS)
Meet Criterion A
EN 61 000-4-11:1994
Voltage Dips, Interruption & Variation
Meet Criterion C
Terminology
DISPLAYPORT Digital display interface standard put forth by the Video Electronics Standards
Association (VESA) since 2006. It defines a new royalty-free, digital audio/video
interconnect, intended to be used primarily between a computer and its display
monitor, or a computer and a home-theater system.
EDID
Extended Display Identification Data. EDID parameters are sent over the DDC link.
EMI
Electro Magnetic Interference.
EMS
Electro Magnetic Susceptibility.
MCCS Monitor Control Command Set standard (VESA)
RFI
Radio Frequency Interference.
QXGA and has four times as many pixels as an WXGA display.
VESA
Video Electronics Standards Association.