Electrical requirements
 - This appliance must be supplied with the proper voltage and frequency, and 
connected to an individual, properly earthed branch circuit, protected by a 
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
 - This appliance is not fitted with other means for disconnection from 
the supply mains having a contact separation in all poles that provide 
full disconnection under overvoltage category III conditions. Means for 
disconnection must be incorporated in the fixed wiring in accordance with 
the wiring rules.
 - You must use a two-wire, single-phase A.C. 220-240 V, 40 A, 50 Hz 
electrical system. (It is also possible to use a four-wire, three-phase.)  
If you connect to aluminum wiring, properly use connectors approved for 
use with aluminum wiring.
 - Check with the local utilities for electrical codes applied in the area. 
Failure to wire the appliance according to governing codes may result in a 
hazardous condition. 
 - After installation, show the customer where the breaker for the appliance is 
located.
WARNING
Electrical work must be 
performed by a legally 
qualified electrician.
 - In accordance with the electrical wiring rules, incorporate the earth leakage 
circuit breaker in the home electrical wire.
 - Follow the specification of the earth leakage circuit breaker as follows. 
  Rated current: 40 A, rated sensitivity current: 30 mA
 
Installation of the earth leakage circuit breaker
 
Electrical connections
1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance 
branch circuit.
2. Connect the power cord.
Connect the power cord in accordance with all governing codes and 
ordinances.
 Single-phase connection (220-240 V ~ 50 Hz) 
Connect the wires in accordance with the instructions given in the 
following table and diagram:
 Three-phase connection (380-415 V 2N~ 50 Hz) 
Separate the L wires and connect them in accordance with the 
instructions given in the following table and diagram:
Electirical cable
Wire connection
E: Yellow / Green  
(Connect to the earth terminal)
N: Grey and Blue together
L: Black and Brown together
(Connect to the live terminal)
E
N
L
Electirical cable
Wire connection
E: Yellow / Green  
(Connect to the earth terminal)
N: Grey and Blue together
L1: Black 
L2: Brown 
(Connect to the live terminal)
Electrical Work
L1
L2
E
N
English