Panasonic CUE18HBEA Operating Guide

Page of 10
4
 OPERATION CONDITION
 OPERATION CONDITION
Use this air conditioner under the following temperature range
(CU-E10HBEA, CU-E15HBEA, CU-E18HBEA)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Maximum
32
23
43
26
Minimum
16
11
-10
-
HEATING
Maximum
30
-
24
18
Minimum
16
-
-10
-
NOTICE:  •  This unit is still able to operate as a cooler with outdoor temperature as low as -10°C in a non-living room, such  
 
  as a computer room, with a room temperature of 16°C or above, and room humidity up to 80%. When the
   
  outdoor temperature drops to -10°C, compressor will be cut off and resume operation again once the  
 
 
  temperature rises to more than -10°C. 
 
   
•  When the outdoor temperature is out of the above temperature range, the heating capacity will drop signifi  cantly  
 
  and outdoor unit might stop for protection control.
(CU-2E15GBE, CU-2E18CBPG, CU-3E18EBE, CU-3E23CBPG, CU-4E27CBPG)
Temperature (°C)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
Maximum
32
23
43
26
Minimum
16
11
16
11
HEATING
Maximum
30
-
24
18
Minimum
16
-
-10
-11
* DBT:  Dry bulb temperature
* WBT:  Wet bulb temperature
OPERATION CONDITION
OPERATION CONDITION