Panasonic CU5E34NBE Operating Guide

Page of 20
18
SPECIFICATIONS
Model No.
Indoor Unit
CS-ME18NKE
CS-ME24NKE
Power Source
Single-phase, 220-230-240 V, 50 Hz
Cooling Capacity
kW
5.15
7.10
BTU/h
17,600 
24,200 
Heating Capacity
kW
6.00
8.50
BTU/h
20,500 
29,000 
Operation 
Sound
Cooling 
Operation
Sound Power Level 
(H/M/L)
dB(A)
59/62/52
62/59/56
Sound Pressure Level 
(H/M/L)
dB(A)
41/38/34
44/41/38
Heating 
Operation
Sound Power Level 
(H/M/L)
dB(A)
58/55/52
61/58/55
Sound Pressure Level 
(H/M/L)
dB(A)
40/37/34
43/40/37
Unit Dimensions (H×W×D)
(Indoor unit : Include panel)
mm
298.0×1,065.0×234.0
298.0×1,065.0×234.0
Net Weight
kg
12.0 
12.0 
Model No.
Outdoor Unit
CU-5E34NBE
Power Source
Single-phase, 220-230-240 V, 50 Hz
Cooling Capacity
kW
10.00 [ 3.50 ~ 11.50 ]
BTU/h
34,100 [ 11,900 ~ 39,200 ]
Heating Capacity
kW
12.00 [ 4.00 ~ 14.50 ]
BTU/h
40,900 [ 13,600 ~ 49,500 ]
Operation 
Sound
Cooling 
Operation
Sound Power Level 
(Hi)
dB(A)
68
Sound Pressure Level 
(Hi)
dB(A)
50
Heating 
Operation
Sound Power Level 
(Hi)
dB(A)
71
Sound Pressure Level 
(Hi)
dB(A)
53
Unit Dimensions (H×W×D)
mm
910.0×940.0×340.0
Net Weight
kg
97.0
01_85264181224000_EN.fm  Page 18  Monday, January 30, 2012  12:30 PM