Panasonic CZKPU3A Operating Guide

Page of 2
9
ECONAVI Function
The amount of human activity is measured by the Human Detection Sensor and the unit operates in energy saving 
mode according to the amount of human activity and indoor humidity.
In case of more physical human activity
In case of less physical human activity
In case of human absence
• 
In Cooling / Dry Mode:
  When in high humid, operates at set temperature.
   When in low humid, operates at higher temperature than 
the set temperature.
• 
In Heating Mode:
   Operates at lower temperature than the set temperature.
• 
In Cooling / Dry Mode:
   Operates at higher temperature than the set temperature.
• 
In Heating Mode:
  When in low humid, operates at set temperature.
   When in high humid, operates at lower temperature than 
the set temperature.
  When absence mode continued for about 
20 minutes
   • 
In Cooling / Dry Mode:
 Operates at higher temperature than that of human 
presence.
   • 
In Heating Mode:
 Operates at lower temperature than that of human 
presence.
  When absence mode continued for about 1 hour
   Operates in the designated human absence operating mode. 
   When setting the temperature for a shipment, energy 
saving operation continues under controlled temperature. 
   (For absence operating mode, see “NOTE” on page 10.)
*  If human is detected in absence operation mode, 
the operation condition is resumed depending on 
the amount of human activity.
WARNING
Do not use ECONAVI function when only a disabled person or infant staying at home.
If a small movement of human body continues for a long time, Panel for cassette (ECONAVI type) 
recognizes human absence and air conditioner may sometimes stop operating. 
10
NOTE
  
When setting the ECONAVI function, it is necessary to use the remote controller provided with the ECONAVI 
function.
  
ON / OFF setting of the ECONAVI function is available by the remote controller.
  
The time between the absence detected by the Human Detection Sensor and the start of absence operation can be 
set by the remote controller (At shipment: 1 hour or every 30 minutes between 30 min and 180 min can be available 
to change).
  
It is possible to choose from 4 types of absence operating mode by the remote controller.
  (1) Without setting 
Energy saving operation under controlled temperature continues.
   
 
 
 When a human is detected, the operation returns depending on the amount of human 
activity. (At shipment)
  (2) Standby mode 
Cooling, dry and heating operation are stopped and only fan (breeze) is operated.
   
 
 
 When a human is detected, the operation returns depending on the amount of human 
activity. 
  (3) Stop mode (No restart) 
 Operation is stopped. After stopped, no operation is restarted although human is 
detected.
  (4) Stop mode (Restart) 
 Operation is stopped. After stopped and when human is detected, the operation is 
restarted depending on the amount of human activity. 
  
Even though the targeted temperature is changed by the ECONAVI function, the set temperature displayed on the 
remote controller will not be changed.
  
Even though the operation is changed to fan operation mode due to the absence operation (standby mode), the 
operation mode displayed on the remote controller will not be changed.
  
When operating the multiple indoor units, the effect of energy saving will be decreased according to the room 
condition.
  
As for the setting method of the ECONAVI function, refer to the Operating Instructions of the remote controller.    
11
Direct Airfl ow and Indirect Airfl ow Function
The Human Detection Sensor can detect the human presence and perform the Direct Airfl ow or Indirect Airfl ow 
function when the human is present within the detection area.
  
Direct Airfl ow 
  Human presence: The air fl ow swings up and down around the human body in cooling/heating mode.
  Human absence: The air fl ow is directed to the fl oor according to the direction setup.
  
Indirect Airfl ow 
  Human presence: The fl ap is set in horizontal direction and the air fl ow is not directed toward the human body.
  Human absence: The air fl ow is directed to the fl oor according to the direction setup.
Swings
Swings
Fixed
Swings
Fixed
Fixed
Indirect Airfl ow
Indirect Airfl ow
Direct Airfl ow
Direct Airfl ow
NOTE
●  When setting the Direct Airflow / Indirect Airflow function, the remote controller provided with Direct Airflow / Indirect 
Airflow function is required.
● When only the ECONAVI function switched on, Direct Airflow / Indirect Airflow function can be operated. 
●  The setting of the Direct Airflow / Indirect Airflow function can be made by the remote controller according to each 
flap of the indoor unit.
●  This function does not guarantee that the air flow will direct toward the human body or not.
●  As for the setting method of the Direct Airflow / Indirect Airflow function, refer to the Operating Instructions of the 
remote controller.     
12
Circulation Function 
When the low fl oor temperature is detected by Floor Temperature Sensor in heating mode or high fl oor temperature is 
detected in cooling mode, the circulation function is operated in order to reduce the temperature irregularity between 
the surroundings of ceiling and fl oor. The circulation function is operated although the unit is in preparation for heating 
in the single split system. 
●  The circulation operation while heating is operated as 
shown below.
  • The air fl ow is automatically changed.
  • 
  is displayed on the remote controller.    
●  When the air conditioner detects human absence, 
set the air fl ow downward in cooling and heating 
mode. Then the unit starts reducing the temperature 
irregularity in a whole room.
  • 
  is displayed on the remote controller.    
●  When circulation operation fi nished or interrupted, 
the following operations are carried out.
  • The fan speed responds to the setting of fan speed.
  •  The air flow responds to the setting of air flow 
direction.    
  • 
  is not displayed on the remote controller.      
●  The circulation operation in preparing for heating 
(thermostat off) is operated as shown below.
  • Flap is positioned in horizontal.
  • 
  is displayed on the remote controller.    
NOTE
●  When setting the circulation function, the remote controller provided with the circulation function is required.
● When only the circulation function switched on, the circulation function can be operated.
● ON/OFF setting of the circulation function can be made by the remote controller according to each indoor unit.
● If the operation mode/fan speed/air flow is changed during circulation operation, the circulation will be interrupted.
  The cases listed below will not carry out the circulation in heating mode.
   <When Human Detection Sensor is detecting human presence>
   •  When the air flow is not directed toward the human body (When setting the indirect airflow or airflow horizontally, 
etc.)
  • When the individual air flow is made at immobilized setting
  • When the specific operation mode setting is made (Defrosting or low discharge temperature) 
  • When setting the changes of the fan speed and air flow are prohibited by central control system
   • When the fan speed is fixed (No automatic air flow setting is made.)
  • When the auto flap setting is made
  <When Human Detection Sensor is not detecting human presence>
  • When the auto flap setting is made
● As for the setting method of the circulation function, refer to the Operating Instructions of the remote controller.
Circulation operation while heating
Circulation operation in preparing for heating
Air fl ow downward in cooling and heating
13
External Device Interlock Function
When taking advantage of the external device interlock function, one of the output of Human Detection Sensor, output 
of thermostat ON or output of operation signal can be selected and it is possible to interlock with the external device.
   Contents of Control
  ●
  
Interlock with the output of Human Detection Sensor output (No interlock with the alarm.)
 
 
Human presence → When human absence detected: Set the operation of external device to OFF.
 
The time change of "Absence detection time setting" can change timing of operation OFF. 
 
Human absence →  When human presence detected: Set the operation of external device to ON.
  ●
  
Interlock with human detection sensor output (Interlock with air conditioner.)   
    When the indoor unit is operated: Operation of external device is switched ON.
    When the indoor unit is stopped: Operation of external device is switched OFF. 
  ●
  
Interlock with thermostat output  
    When the thermostat is switched ON: Operation of external device is switched ON.
    When the thermostat is switched OFF: Operation of external device is switched OFF.
NOTE
●  The external output signal from the air conditioner is supplied for the purpose of controlling the external devices. 
   If the air conditioner does not operate, take measures that the movement of external connecting devices can 
transfer to the safety zone in advance.
●  The external output signal from the air conditioner is turned off when the blackout occurs. If any special 
considerations are needed in case of blackout, provide an external circuit.
●  As for the setting method of the external device interlock, refer to the Operating Instructions of the remote controller.
●  The setting of valid or invalid of the external device interlock function is possible.
●  It is possible to make setting the time (setting at shipment: 0 min) from absence detection until switching off the 
external unit operation. (0 ~ 60 min or 1-minute interval)
●  In order to make setting of the external device interlock, it is necessary to use the remote controller provided with 
the external device interlock function.
14
WARNING
 
For safety, be sure to turn the air conditioner off and dis-
connect the power before cleaning.
(Otherwise, electric shock or injury may result because 
the fan is rotating at high speed.)
 
Do not pour water on the indoor unit.
(This may damage the internal components and cause 
an electric shock hazard.)
CAUTION
 
Never use solvents or harsh chemicals. Also, do not wipe 
plastic parts using very hot water.
(This may cause deformation or change in colour.)
 
Some metal edges and fi ns are sharp. Be careful when 
you clean those parts.
(Injury may result.)
 
Use a fi rm stool or ladder when cleaning an indoor unit 
installed in high locations.
 
The internal coil and other components of the outdoor unit 
must be cleaned periodically.
• Consult your dealer or service center.
Maintenance 
Indoor Unit
 (e.g. Type U2)
Air outlet
Air intake
Wipe with a soft cloth.
(If it is very dirty, use 
a cloth moistened with 
water.)
If the human detection sensor or fl oor 
temperature sensor becomes dirty, 
wipe off with a dry soft cloth. 
In case of heavy dirt, mix a tiny amount 
of neutral detergent with water and 
soak it into a soft cloth, squeeze well 
and gently wipe off the dirt. Then, wipe 
with a soft dry cloth.
15
Troubleshooting
Check before consulting or requesting services.
Symptom
Cause / Countermeasure
Sensor
Unable to detect human presence
 Are there any objects below Human Detection Sensor?
   → Move it to other places not to disturb detection.
  Human presence is judged by detecting heat transfer and 
temperature change.
     The cases listed below may judge no human presence.
    •Small difference between body temp. and room temp.
    (In case of over 30°C room temperature)
    •Away from Human Detection Sensor
    •Small exposed area of skin
 Does Human Detection Sensor get dirty?
   → Wipe Sensor with a clean soft cloth (page 14).
Air fl ow is not directed despite setting of 
Direct Airfl ow.
 Human Detection Sensor may not detect presence.
   → See Symptom’s “Unable to detect human presence”. 
  Direct Airfl ow might be invalid by individual air fl ow direction 
fi xed setting.
   → Cancel it by remote controller. 
 Air fl ow is not directed according to locations.
   (This function does not guarantee the air fl ow is directed.)
   → Fix the fl ap position so that the air fl ow can be directed.
Air fl ow is directed despite setting of 
Indirect Airfl ow.
  Human motion sensor may not detect human presence.
   → See Symptom “Unable to detect human presence”.  
 Indirect Airfl ow might be invalid by individual air fl ow direction 
fi xed setting.
   → Cancel it by remote controller.  
 Air fl ow is directed according to locations. 
   (This function does not guarantee the air fl ow is not directed.)
   →  Fix the fl ap position not to make the air fl ow directed toward 
human body.
Circulation operation does not start despite 
setting of circulation function.
  Circulation operation cannot always start immediately after 
setting the circulation function. 
  Air conditioner itself determines necessity of circulation 
operation and starts and stops automatically. 
  Floor temperature sensor might be infl uenced by the 
temperature for measuring average temperature of the fl oor 
temperature within detection area if any heat source exists. 
Affected by high fl oor temperature detected, circulation 
operation may not sometimes start.
   →  It is suggested that heat sources be moved out of detection 
area.
Circulation operation was canceled.
  When air conditioner itself determines circulation operation is 
unnecessary, it stops automatically. 
  If air fl ow direction or fan speed is changed while operating, it 
is temporarily canceled.
16
Symptom
Cause / Countermeasure
Sensor
Fan speed changed arbitrarily.
 Fan speed may sometimes change automatically during 
circulation operation.
External device does not interlock with 
Human Detection Sensor even after external 
device interlock setting was made.
  Human Detection Sensor may not detect human presence.
   → See Symptom’s “Unable to detect human presence”. 
  External device interlock mode might be set in the air 
conditioner interlock.
   → Change it to sensor interlock mode by remote controller.
    (Refer to Operating Instructions of remote controller.)
  It takes 2 to 5 minutes until Human Detection Sensor 
recognizes human absence after human leaves.
  The time setting until operation of external device turned off 
after the Human Detection Sensor recognizes human absence 
might be set longer. 
   →  Set the above setting time to 0-minute by remote controller. 
(Refer to Operating Instructions of remote controller.) It 
takes 2 to 5 minutes until human absence is recognized by 
Human Detection Sensor. 
Remote controller
ECONAVI
 is displayed.
  Sensor failure might be occurred or installation is not made 
properly. 
   →  Set the ECONAVI function to OFF by remote controller and 
consult at the shop you purchased. 
ECONAVI
 is not displayed on remote 
controller.
  Is the indoor unit stopped?
   →  Set the indoor unit to temporarily operate and check the 
display. 
  Is the operation mode set in air fl ow? 
   →  Set to the operation mode temporarily excepting air fl ow 
and check the display.
 Is the ECONAVI function set to OFF?
   →  Set the ECONAVI function to ON by the remote controller.  
  The remote controller might not be provided with the 
ECONAVI function. 
   →  If no content of ECONAVI function is described in the 
Operating Instructions of remote controller, the remote 
controller is not provided with the ECONAVI function. 
Consult the shop you purchased.
  The indoor unit might not be provided with the ECONAVI 
function. 
   →  If the symptom does not change even after remote control 
operation, the indoor unit is not provided with the ECONAVI 
function. Consult the shop you purchased. 