Panasonic CUUE18RKE Operating Guide

Page of 52
8
Cleaning instructions
To ensure optimal performance of the unit, 
cleaning has to be carried out at regular intervals. 
Dirty unit may cause malfunction and you may 
see error code “H99”. Please consult authorised 
dealer.
• Switch off the power supply and unplug before 
cleaning.
• Do not touch the aluminium fi n, sharp parts may 
cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap (  pH 7) or neutral household 
detergent.
• Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft, 
dry cloth.
Front panel
Wash gently and dry.
Remove the front panel
POWER
TIMER
POWERFUL
QUIET
Raise
1
Pull out
2
Close it securely
1
 Insert at both sides
POWER
TIMER
POWERFUL
QUIET
2
 Close down
3
 Press both ends of the front panel
4
 Press at center of the front panel
POWER
TIMER
POWERFUL
QUIET
Aluminium fin
Front panel
Air filters
Indoor unit
Air Purifying Filter
Air fi lters
Every 2 weeks
• Wash/rinse the fi lters gently with 
water to avoid damage to the fi lter 
surface.
• Dry the fi lters thoroughly under shade, away from 
fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lter
Attach air fi lter
Insert into the unit
Air Purifying Filter
Air Purifying Filter
• Do not wash the air purifying fi lter.
• Replace the fi lter every 10 years or replace any 
damaged fi lter. Part no.: CZ-SA32P
For seasonal inspection after extended non-
use
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select COOL/
HEAT operation. After 15 minutes of operation, 
it is normal to have the following temperature 
difference between air inlet and air outlet vents: 
COOL: ≥ 8 °C
  
HEAT: ≥ 14 °C
For extended non-use
• Activate HEAT mode for 2~3 hours to remove 
moisture left in the internal parts thoroughly to 
prevent mould growth.
• Turn off the power supply and unplug.
• Remove the remote control batteries.