Panasonic rc-sc90y Operating Guide

Page of 1
9
Preparation before installation
Dimension
• There should not be any obstacles surrounding
the unit.
• Prepare an installation hole that is only slightly
bigger than the cabinet size.
• Left and right side of the unit should be at least
15cm away from the wall.


15
Fence 
or likewise
Less than 20cm
WALL
CEILING
Over 15cm
Ov
er 50cm
45cm
Over 15cm
34.6cm
58cm
50
 
20 
34.6 
15 
15 
45 
Remove the front intake grille
1
Push and release.
Pull up the front intake grille about 90° and
slide it slightly to the left to unhook the tabs.
90°
AIR CONDITIONER INSTALLATION
AIR CONDITIONER INSTALLATION
Installation procedures
58 
Selecting the best location
• Install the unit to the nearest power outlet.
• Power supply point shall be the place where there is ease for access for power
disconnection in case of emergency.
• The air conditioner should be installed in a dry place where there are no draughts.
• Condensation from the air conditioner must be drained to an appropriate location.
• Do not install in a location where flammable gas leaks are a possibility.
• Usage in locations where the air is salty such as coastal areas or near hot spas, or where sulphurous gas is generated,
may lead to a malfunction. Please consult your dealer.
• Select an installation location which is rigid and strong enough to support or hold the unit and select a location for
easy maintenance.





9
RC-PC70/90Y(09-13)
1/30/01, 10:56 AM
9