Panasonic CUPW9GKX Operating Guide

Page of 10
38
 
 
Indoor Unit
Outdoor Unit
Test conditions
1.  Cooling: Indoor Dry Bulb Temp. (°C) 27  
Outdoor  Dry  Bulb Temp.  (°C)  35 
 
  Wet Bulb Temp. (°C) 19  
 
Wet  Bulb Temp.  (°C)  24 
Heating: Indoor Dry Bulb Temp. (°C) 20  
Outdoor  Dry  Bulb  Temp.  (°C)  7 
 
  Wet Bulb Temp. (°C) 12 (MAX)   
Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
 
 
 Model
 
 
 CS-PW9GKX
CU-PW9GKX
 
 
CS-PW12GKX
CU-PW12GKX
COOL
HEAT
COOL
HEAT
Single, 230V, 50Hz
Single, 230V, 50Hz
 
Power/Current
[kW]
0.825
0.785
1.055
1.050
[A]
3.90
3.70
5.00
4.90
 
  Refrigerant
[kg]
R410A
0.800
R410A
0.980
  Cooling Capacity
[kW]
2.650
3.400
 
 Heating Capacity
[kW]
2.850
3.800
Noise Level
JIS C 9612 
[<70 dB(A)]
[dB(A)]
   
39
39
39
39
Conditions 
1m Distance
Max. cooling/
heating 
operation
48
49
49
50
Sound power 
level
[dB(A)]
   
50
50
50
50
61
62
62
63
 
 Air Circulation
[m
3
/min.]
10.3
10.3
9.0
9.2
 
 Product Weight
[kg]
   
7.5
9.0
27
30
 
Dimensions (L x W x H)
[mm]
   
770×205×250
799×183×280
650×230×530
780×289×540
kg
   produCt SpeCifiCation
  produCt SpeCifiCation
F566809_EN1.indd   38