Panasonic S-ICX Manual

Page of 78
S-ICX-50-200
S-ICX (International) issued October 2000
77
Cabling Specifications
Maximum Cabling Distances  
Voice/Data Transmission
Voice Path from Digital Keyphones to the S-ICX  
VB-44330
PC Attendant Console 96
(1 Ext. + 1 DSS per Console unit)
4
4
VB-44331
PC Attendant Console 384
(1 Ext. + up to 5 DSSs per Console unit)
2
2
VB-44332
PC Phone
(1 Ext. per PC Phone unit)
24
56
(none)
PC Customize Tool
1
1
Loop Type Resistance
Resistance
Cable Gauge (AWG)
Maximum Cabling Length in 
Meters (distance from the S-ICX)
Key Telephone, EM/24
40 Ohms
22
360
24
240
26
120
DSS/72
20 Ohms
22
180
24
120
26
60
SLT
100 Ohms
22
900
24
600
26
300
Doorphone (loop between the 
S-ICX and Doorphone 
Adapters)
10 Ohms
22
90
24
60
26
30
Doorphone (loop between the 
Doorphone Adapter and the 
Doorphone)
10 Ohms
22
90
24
60
26
30
NOTE: If a Voice Recognition Adapter is installed with the telephone, the measured resistance must be less than 20 Ohms 
and the maximum cabling distance reduced in half compared to a standard key telephone.
Channel
Speed
Overall communications path
256 kbps
D-channel data
16 kbps
B-channel data
64 kbps
Part No.
Description
Capacities
CPC-HS 
Cabinet
CPC-HM 
Cabinet