STATION DISTINCTIVE RINGING
Description:
Extension basis, the different ringing pattern and frequency can be selected.
This feature is available for Key telephone and DSLT.
Benefits:
  Not only Trunk basis, also Extension basis distinctive Ringing Assignment is 
available.
STATION MESSAGE DETAIL RECORDING (SMDR/CALL LOGGING)
Description:
By attaching a serial printer to the RS232C port, a detailed record of all incoming and outgoing 
calls, can be kept for future reference.
Through programming, the titles for each page can be removed to allow for connection to call 
accounting services.
The following is an explanation concerning the output format and display contents for call data:
SMDR Output Data Format 
Condition Code:  
Call Start Time (Month/Day, Hour:Minute:Second)
Call Duration Time (Hours:Minutes:Seconds)
Trunk User No. (Internal Line No. 0 to 9999, or Trunk No. C1 to C576)
INCOMING CALLS:
OUTGOING CALLS:
I
Incoming Call
F
Call Forward Outside
D
DID Incoming Call
H
Hold Outgoing Call
h
Hold Incoming Call
L
LCR Outgoing Call
N
Network Incoming Call
O
Outgoing (non-LCR) Call
S
DISA Incoming Call
T
Transfer Outgoing Call
t
Transfer Incoming Call
W
Closed Numbering Outgoing Call
A
Abandoned Incoming Call
Format #1
T MM/DD HH:MM:SS HH:MM:SS NNNN TTTT dddddddddddddddddddddddd aaaaaaaaaa vvvv
H
Format #2
T MM/DD HH:MM:SS HH:MM:SS NNNN TTTT dddddddddddddddddddddddd aaaaaaaaaa vvvv 
dddddddddddddddd cccccccc
 
MM:SS
H
6
7
5
4
3
2
1
8
6
7
5
4
3
2
1
8
11
10
9
12
12
7
8
9
10
11
6
5
4
1
3
2