Panasonic KX-TD612E Manual
General Features
244
Features Guide
System Programming and Diagnosis with Personal
Computer
Computer
Description
This system can be programmed and administered using a personal computer (PC) connected
to a Serial Interface (RS-232C) port. There are 3 types of possible connections.
to a Serial Interface (RS-232C) port. There are 3 types of possible connections.
•
PC — KX-TD612
•
PC — Central Office — KX-TD612
•
PC — KX-TD612 — Central Office — KX-TD612
Refer to 2.2.7 System Programming and Diagnosis with Personal Computer in Installation
Manual. There are 4 functions as follows.
Manual. There are 4 functions as follows.
On-Site/Remote System Administration by PC Programming Software
By connecting a personal computer (PC) to your system, system programming and
maintenance can be performed. There are 2 types of PC programming software. One is the
standard version and the other is the feature limited version. The password (4-7 digits)
determines which of the software is set up. The password to set up the standard version is
[TD612] only. And the one to set up the feature limited version is programmable (default: no
password). Following programming is available in the feature limited version.
1. System Programming [000] through [024] and [811].
2. Station Programming
maintenance can be performed. There are 2 types of PC programming software. One is the
standard version and the other is the feature limited version. The password (4-7 digits)
determines which of the software is set up. The password to set up the standard version is
[TD612] only. And the one to set up the feature limited version is programmable (default: no
password). Following programming is available in the feature limited version.
1. System Programming [000] through [024] and [811].
2. Station Programming
On-Site/Remote Software Download
You can download the software of the KX-TD612 by using the PC connected to the main unit.
Remote software download is to be possible through the Integrated Services Digital Network.
Remote software download is to be possible through the Integrated Services Digital Network.
On-Site/Remote Software System Change
Allows you to change the systems leaving the power switch on by a digital proprietary
telephone or PC connected to a Serial Interface (RS-232C) port of your system. You can set up
the system again after a new system is adopted.
telephone or PC connected to a Serial Interface (RS-232C) port of your system. You can set up
the system again after a new system is adopted.
On-Site/Remote Maintenance
You can perform the remote maintenance and programming as well as the on-site maintenance
by using a personal computer through the Integrated Services Digital Network.
by using a personal computer through the Integrated Services Digital Network.
Conditions
•
A digital proprietary telephone can be used to perform System Programming.
•
To connect with a remote KX-TD612, the system password of KX-TD612 is necessary.
•
Least Cost Routing (LCR) feature does not work, when making a call on "PC — KX-
TD612 — Central Office — KX-TD612" connection.
TD612 — Central Office — KX-TD612" connection.