General Features
Features Guide
255
Toll Restriction
Description
Toll restriction is used in conjunction with the assigned Class of Service, and can prohibit 
certain extension users from placing unauthorised toll calls.
Every extension is programmed to belong to one of 8 Classes of Service. Each Class of Service 
is programmed to have a toll restriction level for day mode and night mode.
There are 8 toll restriction levels available. Toll restriction level 1 is the highest level and the 
level 8 is the lowest. That is, level 1 allows all toll calls and levels 7 and 8 disallow all toll calls. 
Levels 2 through 6 are used to restrict calls by combining pre-programmed deny and excepted 
code tables.
The pre-assigned emergency numbers such as "999" and "112" are allowed to call in any level.
Denied Code Tables
An outgoing outside call made by an extension with a toll restriction level between 2 and 6 is 
first checked against the selected Denied Code Tables. If the leading 7 digits of the dialled 
number (not including the line access code) are not found in the table, the call is made. There 
are 5 system programmes for Denied Code Tables: [301-305] TRS Denied Code Entry for 
Levels 2 through 6: each programme is used to make up a Denied Code Table for Levels 2 
through 6 respectively.
Complete every table by storing numbers that are to be prohibited. These numbers are defined 
as denied codes. Each table can store up to 20 denied codes, each of which consisting of 7 
digits.
Excepted Code Tables
These tables are used to override a programmed denied code. A call denied by the selected 
Denied Code Tables is checked against the selected Excepted Code Tables, and if a match is 
found, the call is made.
There are 5 system programmes for these tables:
[306]-[310] TRS Excepted Code Entry for Levels 2 through 6: each programming is 
used to make up an Excepted Code Table for Levels 2 through 6. Complete every table by 
storing numbers that are exceptions to the denied codes. These numbers are defined as 
excepted codes. Each table can store up to 20 excepted codes, each of which consisting of 
7 digits.
Applicable Denied and Excepted Code Tables depend on the assigned toll restriction level 
of an extension as follows: