General Features
Features Guide
271
This feature requires assigning an UCD group in System Programming. An extension can 
belong to 2 or more UCD groups.
The floating number can be assigned on a hunting group basis. The UCD group is based on 
the hunting group.
It is possible to set the log-in or log-out status on an extension basis. An UCD call can be 
sent to an extension in log-in status within the UCD group, but cannot be sent to extensions 
in log-out status. If the extension would like to leave the group temporarily, the extension 
sets the log-out status by the feature number to prevent UCD calls being sent to his/her 
extension. When the extension re-joins the group, the extension sets the log-in status.
If all extensions are in the log-out status, the extensions assigned to Intelligent Call 
Handling table 61 (day mode) and 62 (night mode) will ring.
If a UCD call is not answered within the intercept time ([203] Intercept Time), the call will 
go to the intercept extension ([457] Intercept Extension).
For time tables to work, you need to set the queue length to 1 or greater in programme [131] 
Hunting Group Assignment.
Programming Guide References
[106] Station Hunting Type
[131] Hunting Group Assignment
[133] Hunting Overflow
[134-135] Hunting Intercept — Day/Night
[137-138] Time Table Assignment — Day/Night
[139] Time Table
[453] Other Extension Ringing Assignment
[456] Call Handling When All Busy
[457] Intercept Extension
[813] Floating Number Assignment
Features Guide References
User Manual References