Panasonic S-ICX Manual

Page of 354
62
S-ICX (International) issued January 2000
S-ICX-10-700
Chapter 3. System Features
Section 700 - Operation
ISDN Charge Data (Format #2 only - originator number applies to ISDN only) - Not Used (Format #2 
only) Future Use
 
Incoming Ringing Time (Format #2 only) (MM=00 to 99 / SS=00 to 59)
H
 
Carriage Return Line Feed
Hardware Requirements
A printer or external call accounting system is required to receive Call Logging data.
Considerations
A call must be answered to generate Call Logging data (e.g., answered by Voicemail, call pickup, 
etc.)
You can specify which type of Call Logging data format is sent (i.e., either Format 1 or 2).
System Speed Dial TRS (Call Barring) Override
Description
System Speed Dial (SSD) numbers may be used to outdial calls from extensions that otherwise have 
outgoing call restrictions (i.e., Toll Restriction Service [TRS] Call Barring). 
Hardware Requirements
N/A
Considerations
N/A
Toll Restriction Service (Call Barring)
Description
Toll Restriction Service (TRS) - Call Barring allows access levels, including the prohibition of long 
distance calls or after-hours calls, to be assigned to specific extensions or trunks. This minimizes non-
business related calls and reduces phone bills by only allowing long distance calls over designated 
lines.
TRS (Call Barring) can be used in conjunction with Automatic Route Selection (ARS). 
TRS (Call Barring ) classes are set on an extension and trunk basis. Up to 50 TRS (Call 
Barring) classes can be assigned.
Each TRS (Call Barring) class is then assigned to a TRS level. This level is used as the basis 
for allowing or restricting calls.
There are 10 TRS (Call Barring ) levels available: 0 denies all calls, 1-8 may be partially 
restrictive per assignments, and 9 allows all calls.
TRS (Call Barring) can restrict the number of digits dialled (1 to 20 digits limit or no limit).
10