Panasonic ICX Manual

Page of 91
ICX-50-200
ICX (International) issued October 2000
79
Section 200 - General Description      
Chapter 6 - Specifications      
Overview
This chapter provides detailed lists of all system specifications in an easy-to-follow table format.
Note: The following specifications are subject to change without notice.
Electrical Characteristics
Power Supply  
Battery Backup  
Equipment
Specification/Requirements
All ICX Cabinets
100-240 volts AC + 10% 60 Hz
Primary Power -
Input @ AC:
AC Frequency:
Watts per cabinet (continuous):
Watts for 6-cabinet system (continuous):
85 to 276 volts AC
50/60 Hz
360 watts
2,160 watts
Maximum Peak AC Input Current -
1 cabinet:
2 cabinets:
3 cabinets:
4 cabinets:
5 cabinets:
6 cabinets:
3.3 A
6.6 A
9.9 A
13.2 A
16.5 A
19.8 A
DC Voltage Output Specification:
–24 volts DC (–26.0 to –27.6 volts DC)
+5 volts DC (+4.9 to +5.3 volts DC)
AEC (8-circuit card that supports single-line devices 
such as rotary and DTMF standard phones; FAX 
machines; dictation equipment; etc.) -
Ring Voltage:
Ringing Capability:
150 volts p-p
2.0 REN per circuit
Traffic Rating Characteristics:
5.4 HCS per station system-wide
ICX key telephones
3 watts maximum (powered from the ICX)
Equipment
Specification
Battery Pack: (Part No. VB-44025)
Capacity (with maximum traffic):
30 minutes
Battery Charger Characteristics -
Charger:
Nominal Voltage:
Battery Discharge Cut-Off Voltage:
Floating charge
27.2 volts
21.0 + 0.3 volts DC
CHAPTER 6 - SPECIFICATIONS