Panasonic DP-180 Instruction Manual

Page of 194
175
P
roblem Solv
ing
■ Internet Fax Return Receipt Error Messages
Error messages that are printed on the Internet Fax Return Receipt when remote programming of the Auto Dialler via 
email fails.
Error Message
Possible Cause
1
Format Error : <@command block, the 
"@end" command is missing.>
The block termination command "@end" is missing in the 
"@command" block, add the "@end" command and try again.
2
Format Error : <@begin block, the "@begin" 
command is missing.>
The block start command "@begin" is missing in the "@begin" block, 
add the "@begin" command and try again.
3
Format Error : <@begin block, the "@end" 
command is missing.>
 The block termination command "@end" is missing in the "@begin" 
block, add the "@end" command and try again.
4
Format Error : <@system block, the "@end" 
command is missing.>
The block termination command "@end" is missing in the "@system" 
block, add the "@end" command and try again.
5
Format Error : <@sender block, the "@end" 
command is missing.>
The block termination command "@end" is missing in the "@sender" 
block, add the "@end" command and try again.
6
Format Error : <@domain block, the 
"@end" command is missing.>
The block termination command "@end" is missing in the "@domain" 
block, add the "@end" command and try again.
7
Format Error : <@program block, the 
"@end" command is missing.>
The block termination command "@end" is missing in the 
"@program" block, add the "@end" command and try again.
8
Format Error : <@system block, the 
"@system" command is missing.>
The system block start command "@system" is missing in the 
"@system" block, add the "@system" command and try again.
9
Permission denied : <Fax Forward 
parameter is set to "Valid".>
Change the Fax Forward parameter to "Invalid" and try again.
10 Permission denied : <Fax machine is busy 
performing a task.>
Try again later when the machine is not busy.
11 Error : <Programmed ABBR overwrite 
prohibited. Use open ABBR only.>
Cannot overwrite existing programmed data, use the "Delete" 
command to erase the existing data first.
12 Permission denied : <Password is 
incorrect.>
Correct the password and try again.
13 Permission denied : <Remote Dialler 
Update parameter is set to "Invalid".>
Set the Remote Dialler Update parameter to "Valid".
14 Format Error : <error line>
The format of the Entry is incorrect / incomplete or the data string for 
each station is not defined within a single line.
15 Warning : <error line>
The format of the Entry is incorrect or the number of characters 
entered, exceed the maximum allowed in the field. Correct it and try 
again.
16 Warning : Field limit exceeded<error line>
The maximum number of Station Name, Domain Name, Sender 
Name, Program Name, etc were exceeded.