Puls CD5.121 DC/DC Converter Specification Guide

Page of 21
 
 
CD5.121
 
 
CD-Series 
DC/DC Converter 12V, 8A 
 
 
12.  EMC 
The DC/DC converter is suitable for applications in industrial environment as well as in residential, commercial and 
light industry environment without any restrictions. The CE mark indicates conformance with EMC guideline 
89/336/EEC, 93/68/EEC and 2004/108/EC and the low-voltage directive (LVD) 73/23/EWG and 2006/95/EC. A detailed EMC 
report is available on request. 
 
EMC Immunity 
Generic standards: EN 61000-6-1 and EN 61000-6-2 
Electrostatic discharge  
EN 61000-4-2 
Contact discharge 
Air discharge 
8kV 
15kV 
Criterion A 
Criterion A 
Electromagnetic RF field 
EN 61000-4-3 
80MHz-2.7GHz 
10V/m 
Criterion A 
Fast transients (Burst) EN 
61000-4-4 
Input 
lines 
Output lines 
4kV 
2kV 
Criterion A 
Criterion A 
Surge voltage on input 
EN 61000-4-5 
+ Æ - 
1kV  
Criterion A 
 
 
+/- Æ chassis ground 
2kV Criterion 
Surge voltage on output 
EN 61000-4-5 
+ Æ - 
+ / - Æ chassis ground 
500V 
500V 
Criterion A 
Criterion A 
Conducted disturbance 
EN 61000-4-6 0.15-80MHz 
10V 
Criterion 
Criterions: 
A:    DC/DC converter shows normal operation behavior within the defined limits.  
C:    Temporary loss of function is possible. DC/DC converter may shut-down and restarts by itself. No damage or hazards for the DC/DC 
converter will occur. 
 
 
EMC Emission 
Generic standards: EN 61000-6-3 and EN 61000-6-4 
Conducted emission  
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 
Class B, input lines 
(Limits for DC power ports) 
Radiated emission 
EN 55011, EN 55022 
Class B 
This device complies with FCC Part 15 rules. 
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation. 
 
 
Switching frequency 
 
 
Variable between 90kHz and 145kHz depending on load and input voltage  
(output current > 0.5A) 
 
Oct 2009 / Rev. 1.3  DS-CD5.121-EN 
All parameters are specified at 12V, 8A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 