Moxa PTC-101-M-ST-HV Specification Guide

Page of 3
2
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Ethernet Media Converters
Environmental Type Tests
Test
Description
Test Levels
IEC 60068-2-1
Cold, operating (power ON/OFF)
Test Ad
-40°C, 48 hours 
IEC 60068-2-3
Damp heat, steady state, operating
Test Ca
85°C, 95% R.H., 24 hours 
IEC 60068-2-14
Changing temperature, operating
Test Nb
-40 to 85°C, Ramp rate: 3°C/min, 8 cycles
IEC 60068-2-48
IEC 60068-2-1
Cold, storage
Test Ad
-40°C, 12 hours
IEC 60068-2-48
IEC 60068-2-3
Damp heat, steady state, storage
Test Ca
90°C, 95% R.H., 24 hours
IEC 60068-2-32
ISTA-2A
Freefall, package
Test Ed
90 cm
IEC 60068-2-34
Random vibration, package
Test Fd
3 grms (5 to 500 Hz)
IEC 61850-3
IEC 60870-2-2
IEC 60068-2-6
IEC 60721-3-3
Vibration, operating
Class Cm (3M6, 4M6) 
20 m/s² (9 to 200 Hz)  
15 m/s² (200 to 500 Hz)
IEC 61850-3
IEC 60870-2-2
IEC 60068-2-27
IEC 60721-3-3
Shock, operating
Class Cm (3M6, 4M6) 
300 m/s², 11 ms
144.15 mm (5.68 in)
67.4 mm (2.65 in)
15 mm
(0.59 in)
19 mm
(0.75 in)
26.2 mm
(1.03 in)
26.06 mm
(1.03 in)
30.5 mm
(1.2 in)
34 mm
(1.34 in)
51.6 mm (2.03 in)
54 mm (2.13 in)
67 mm (2.64 in)
101.4 mm (3.99 in)
111.4 mm (4.39 in)
123.46 mm (4.86 in)
135.1 mm (5.32 in)
66.65 mm (2.62 in)
PTC-101-M-ST-HV
Panel Mounting Kit
 
(Optional)
Rear View
Front View
Side View
Dimensions
PTC-101-M-ST-HV (other models available by request)