Molex ENQ3135M050 Industrial Patch Cable Specification Guide

Page of 1
www.molex.com
351
RJ-Lnxx-to-RJ-45  RJ-Lnxx RJ-45 Male, Double-Ended
Cable Type
Cable Jacket
Wire Size
AWG 
Wiring
Length
Male Straight Industrial-to-Industrial
Male Straight Industrial-to-Standard
Engineering No.
Standard Order No.
Engineering No.
Standard Order No.
Shielded Stranded Proplex™ 
Kevlar Wrapped (ENP)
PUR Kevlar Wrapped
26
10 Base-T (4 wire)
1.0m
ENP1115M010
130050-0076
ENP1135M010
130050-0093
568A (8 wire)
ENP2115M010
130050-0122
ENP2135M010
130050-0140
568B (8 wire)
ENP3115M010
130050-0170
ENP3135M010
130050-8036
Shielded Solid Core (ENS)
PUR
24
10 Base-T (4 wire)
1.0m
ENS1115M010
130050-0284
568A (8 wire)
ENS2115M010
130050-0336
ENS2135M010
130050-0371
568B (8 wire)
ENS3115M010
130050-0412
ENS3135M010
130050-0429
Shielded Solid Core (ENV)
PUR
24
568B (8 wire)
1.0m
ENV3115M010
130050-8025
ENV3135M010
130050-8029
Unshielded Stranded (ENQ)
PVC
24
568B (8 wire)
1.0m
ENQ3115M010
130050-0251
ENQ3135M010
130050-0262
Note: Sales drawings for all standard order numbers are available on molex.com
*Kevlar is a trademark of DuPont
Industrial Ethernet 
Brad
®
 RJ-Lnxx
®
 RJ-45 
Double-Ended Cordsets
130050
Threaded
Male-Male Straight
RJ-45 (Industrial)-to- 
RJ-45 (Industrial) and  
RJ-45 (Industrial)-to- 
RJ-45 (Standard)
Features and Benefits
• 
RJ-45 plug, combined with industrially proven form 
factor provides a secure robust connection that 
protects against the effects of vibration and accidental 
disconnection
• 
Category 5e compliant
• 
Several cable options available
• 
Achieves IEC IP67 rates seal when mated with an 
RJ-Lnxx
®
 receptacle
ENS—Shielded Solid Core Cable
Physical
Cable: Solid Core
Conductors:  24 AWG solid bare Copper, 0.020" (0.510mm)
Insulation:  0.009" (0.229mm) of cellular polyethylene 
0.04" (1.0mm) nominal diameter
Pair:  Two insulated conductors twisted together, lay lengths 
varied between pairs to minimize cross talk
Core: Four pairs cabled together
Binder:  Polyester tape, 20% overlay minimum 
Shield:  Aluminum/Polyester tape, 20% overlay minimum 
Drain Wire:  24 AWG stranded (7/32") Tin-plated Copper
Jacket:  Black Polyurethane 0.025" (.635mm) nominal 
thickness
Operating Temperature: -20 to +80°C
Diameter: 0.245" (6.223mm) nominal
TIA/EIA Rating: Category 5e
ENQ—Unshielded Stranded Cable
Physical
Cable: Stranded
Conductors:  24 AWG stranded tinned Copper
Insulation:  Polyolefin 0.037" (0.94mm) nominal diameter
Pair:  Two insulated conductors twisted together, lay lengths 
varied between pairs to minimize cross talk
Core: Four pairs cabled together
Binder:  Polyester tape, 20% overlay minimum 
Operating Temperature: -20 to +80°C
Jacket:  PVC 0.025" (0.635mm) nominal thickness
Diameter: 0.220" (5.588mm) nominal
TIA/EIA Rating: Category 5e
ENP—Shielded Standard Proplex™  
Kevlar* Wrapped Cable
Physical
Cable: Proplex Kevlar wrapped
Conductors:  26 AWG stranded bare Copper
Insulation:  Color coded HFFR, Halogen free, 0.035" 
(0.90mm) nominal diameter
Pair:  Cabled with Kevlar strength member and tape wrapped
Core: Four pairs cabled together
Shield:  Inner—Aluminum Mylar, 100% coverage  
Outer—Tinned Copper Braid: 80% coverage
Operating Temperature: -70 to +105°C
Jacket:  Black Urethane 0.059" (1.5mm) nominal thickness
Diameter: 0.287" (7.3mm) nominal
TIA/EIA Rating: Category 5e
ENV—Shielded Solid Core
Physical
Cable: Solid core
Conductors: 24 AWG solid bare Copper, 0.020" (0.510mm)
Insulation: Polyethylene, 0.042" (1.07mm) nominal diameter 
Pair:  Two insulated conductors twisted together, lay lengths 
varied between pairs to minimize cross talk
Core: Four pairs cabled together
Binder: Polyester tape, 20% overlay minimum
Shield: Aluminum/Polyester tape
Drain Wire: 24 AWG Tin Copper matt Polyurethane
Jacket:  Black Polyurethane UV stable, 0.0244" (0.620mm) 
nominal thickness
Diameter: 0.244" (6.200mm) nominal
Operating Temperature: -20 to 60°C
Wiring Sequence: Choice of TIA/EIA 568A/B or 10 Base-T
TIA/EIA Rating: Category 5e
Length
Code
Meters
2
M020
5
M050
10
M100
Configuration Code
Build-a-Part Number
ENP1115
M010
Wiring Option
Cable Option
Once an engineering number is created using the configuration code, consult Molex tech support for information regarding any part numbers.