Panduit IUC5C04ABL-CEG CAT 5e Cable Specification Guide

Page of 2
www.panduit.com
s p e c i f i c a t i o n s
Category 5e U/UTP copper cable shall meet or exceed 
the IEC 61156-6 and ANSI/TIA-568-C.2 Category 5e 
standards up to 80 meters. The stranded copper conductors 
shall be 24/7 AWG with high density polyethylene (HDPE) 
insulation. The copper conductors shall be twisted in 
pairs. All pairs shall then be surrounded by a PVC jacket. 
The jacket shall be oil, UV, and abrasion resistant for 
enhanced chemical resistance and mechanical 
performance. The jacket shall be flame retardant (CM) 
for industrial Ethernet applications.
IndustrialNet
 Category 5e U/UTP    
Copper Cable
a p p l i c a t i o n s
t e c h n i c a l   i n f o r m a t i o n
Electrical performance: 
Certified component performance up to 80 meters and exceeds 
the requirements IEC 61156-6 and ANSI/TIA-568-C.2 Category 5e 
at swept frequencies up to 100 MHz
Standard compliances: 
SUN RES OIL RES II (UL1581 Section 480 and 1200)
Conductors/insulators: 
Four pairs of 24/7 AWG stranded copper insulated with high 
density polyethylene (HDPE) insulation     
Insulation diameter:
0.94 – 1.04mm (0.037 – 0.041 in.)
Flame rating:
CM (UL1685)
Installation tension: 
110 N (25 lbf) maximum
Temperature rating:
-20°C to 75°C (-4°F to 167°F) during transport, installation, 
and operation
Cable jacket:
Flame retardant PVC, oil, UV, and abrasion resistant
Cable diameter: 
6.3mm (0.248 in.) nominal
Cable weight: 
23 kg/305m (51 lbs./1000 ft.)    
Packaging:
Packaged 305 meters (1000 feet) on a reel
Package tested to ISTA Procedure 1A  
k e y   f e a t u r e s   a n d   b e n e f i t s
Third party tested   
Cable has been tested by an independent laboratory and complies 
with the electrical standard requirements of IEC 61156-6 Category 
5e and ANSI/TIA-568-C.2 Category 5e standards
Reliability 
Stranded conductors for standard flex applications and ease of 
installation; cable jacket shall be oil, UV, and abrasion resistant for 
enhanced chemical resistance and mechanical performance      
Descending length 
cable markings
Easy identification of remaining cable reduces installation time and 
cable scrap
Packaged on a reel 
Ensures proper performance and provides quick installation  
IndustrialNet
 Category 5e U/UTP     
Copper Cable
CM 4-pair/ 
color Black:  
IUC5C04ABL-CEG    
IndustrialNet
 Category 6/5e   
RJ45 Field Terminable Plug
Field
terminable plug:  ISPS688FAS 
IndustrialNet
 Category 5e 
Shielded 600 V-Rated Patch Cords
CM/CMX: 
*ISTPHCH1MTL
IndustrialNet
 M12 D-Code to 
RJ45 Panel Mount Adapter
Panel
mount adapter:  ICAM12DRJS
Mini-Com
®
 Modular Patch Panel
8-port:  
CDPP8RG
DIN Rail Adapter
1-port: 
CADIN1IW**
*For other lengths, change the length 
designation (1M) of the part number to the desired 
length (0.3M, 0.6M, 2M, 3M, 5M, or 10M); to 
designate color, replace TL (Teal)  
suffix with BL (Black), RD (Red), or YL (Yellow). 
For example, the part number for a 2-meter teal 
patch cord is ISTPHCH2MTL.
**For standard colors other than Off White, 
replace IW in part number with BL (Black), 
EI (Electric Ivory), IG (International Gray), or 
WH (White). 
IndustrialNet
 Category 5e U/UTP Copper 
Cable provides reliability and high performance 
as an integral component of the end-to-end 
solution for industrial Ethernet and Ethernet/IP 
based communications networks. The 4-pair 
high performance cable ensures highest 
availability in conditions seen in industrial 
environments. The cable incorporates a 
durable PVC jacket and is oil, UV, and 
abrasion resistant.
Key applications include:
• 10BASE-T (Ethernet)
• 100BASE-T (Fast Ethernet)
• 1000BASE-T (Gigabit Ethernet)
• Industrial Ethernet 
• Ethernet/IP 
• Downlinks from control panel to the 
  machine area 
• Uplinks featuring gigabit data transmission        
  from the control panel to the consolidation point
S P E C I F I C A T I O N   S H E E T