Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
B-18
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Appendix B      Transceivers, Module Connectors, and Cable Specifications
  Module Connectors
Figure B-11 RJ-45 Interface Cable Connector
Caution
Category 5e and Category 6 cables can store large levels of static electricity because of the dielectric 
properties of the materials used in their construction. Always ground the cables (especially in new cable 
runs) to a suitable and safe earth ground before connecting them to the module.
Caution
To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use foil twisted-pair 
(FTP) cable that is properly grounded at both ends.
RJ-21 Connector 
The RJ-21 connectors (shown in 
) are used on telco modules. Each RJ-21 connector has pins 
for 12 ports.
Note
The RJ-21 connector for the WS-X6624-FXS module has pins for 24 ports. See the 
.
To connect to 10/100BASE-TX RJ-21 telco interfaces, use Category 5 UTP cables with male RJ-21 
connectors, as shown in 
. The WS-X6224-FXS analog interface module also uses an RJ-21 
connector, but the pinout arrangement is different than the 10/100BASE-TX.
H1567
Pin 1
Pin 8
RJ-45 (both ends)
Warning
 
If the symbol of suitability with an overlaid cross appears above a port, you must not connect the 
port to a public network that follows the European Union standards. Connecting the port to this type 
of public network can cause severe personal injury or can damage the unit. 
Statement 1031