Cisco CATALYST 4510R 10 SLOT CHASSIS WITH FAN TRAY Specification Guide

Page of 15
 
 
© 2005 Cisco Systems, Inc. All rights reserved. 
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com. 
Page 10 of 15 
 
 
FAN TRAYS  
Each Cisco Catalyst 4500 Series chassis uses a single fan tray for cooling. All fan trays are composed of independent fans. If one fan fails, the system 
will continue to operate without a significant degradation in cooling. The system will detect and notify the user (through LED, command-line 
interface [CLI], and SNMP) that a fan has failed and the tray needs to be replaced.  
FABRIC-REDUNDANCY MODULES (CISCO CATALYST 4507R AND 4510R ONLY)  
The Cisco Catalyst 4500 Series redundancy scheme uses removable fabric-redundancy modules on the passive backplane to switch traffic to the 
active supervisor engine. There is one fabric-redundancy module per line card. Fabric-redundancy modules and redundant clocks ship standard with 
every Cisco Catalyst 4507R and 4510R chassis. Spare fabric-redundancy modules and clock modules are available for serviceability.  
ENVIRONMENTAL CONDITIONS  
The Cisco Catalyst 4500 Series requires the following conditions: 
 
Operating temperature: 32 to 104ºF (0 to 40ºC)  
 
Storage temperature: –40 to 167ºF (–40 to 75ºC)  
 
Relative humidity: 10 to 90 percent, noncondensing  
 
Operating altitude: –60 to 2000 meters (m)  
REGULATORY STANDARDS COMPLIANCE 
Table 9 lists the regulatory standards compliance of the Cisco Catalyst 4500 Series. 
Table 9.  Regulatory Standards Compliance  
Specification  
Standard  
Regulatory Compliance  
 
CE marking  
Safety 
 
UL 60950  
 
CAN/CSA-C22.2 No. 60950  
 
EN 60950  
 
IEC 60950  
 
TS 001  
 
AS/NZS 3260  
EMC  
 
FCC Part 15 (CFR 47) Class A  
 
ICES-003 Class A  
 
EN55022 Class A  
 
CISPR22 Class A  
 
AS/NZS 3548 Class A  
 
VCCI Class A  
 
EN 55022  
 
EN 55024  
 
EN 61000-6-1  
 
EN 50082-1  
 
EN 61000-3-2  
 
EN 61000-3-3  
 
ETS 300 386