OPERATION
Automatic Turn-On Selection: The PXA series offers two automatic turn-on modes that can be selected on 
the end panel; +12V or DC Offset. Using the DC Offset mode causes the REM terminal wire to have +12V out 
for turning on additional amplifi ers.
•  
Remote Turn-On: Set the switch to +12V to use the remote turn-on lead from the PXA harness. Run 18 
gauge wire from the Remote Turn-On Lead on your source unit to the REM wire on the PXA harness. (Best 
for Lo-Level input)
•  
DC Offset Turn-On: The DC Offset mode detects a 6V DC offset from the HI-Level speaker outputs when 
the source unit has been turned on. (Best for Hi-Level input)
Input Level: The RCA inputs on KICKER PXA amplifi ers are capable of receiving either Hi or Low-level signals 
from your source unit. When using a Hi-Level signal, simply set the Input Level switch on the amplifi er to HI.
HI-PASS Switches: Use the HI-PASS switches behind the protective rubber covering of the amplifi er to set the 
internal crossover. Choose a cutoff of 60Hz, 80Hz, 120Hz, or OFF depending on the confi guration of switches 1 
and 2. Never change the switches with the audio system on!
Input Gain Control: The input gain control is not a volume control. It matches the output of the source unit to 
the input level of the amplifi er. Turn the source unit up to about 3/4 volume (if the source unit goes to 30, turn it 
to 25). Next, slowly turn (clockwise) the gain on the amplifi er up until you can hear audible distortion, then turn it 
down a little.
HI-PASS FILTER
              LO         12V
              HI          DC
INPUT LEVEL
AUTO TURN-ON
60Hz       80Hz     120Hz       OFF 
2015 PX Stereo Amplifier Rev B.indd   4