Sony BC-QM1 Owner's Manual

Page of 5
1
2
3
4
6
7
8
9 10
5
BC-QM1
4-467-217-11(1)
Battery Charger 
Chargeur de Batterie
充电器 
Operating Instructions
Mode d’emploi
© 2013  Sony Corporation   Printed in China
When not using this unit, disconnect the USB cable from its USB 
 
connector and store it.
Maintenance
If this unit gets dirty, wipe it using a soft dry cloth.
 
If this unit gets very dirty, wipe it using a cloth with a little neutral 
 
solvent added, and then wipe it dry.
Do not use thinners, benzine, alcohol, etc., as they will damage the 
 
surface of this unit.
When you use a chemical cleaning cloth, refer to its instruction manual.
 
Using a volatile solvent such as an insecticide or keeping this unit 
 
in contact with a rubber or vinyl product for a long time may cause 
deterioration or damage to this unit.
Features
The BC-QM1 Battery Charger can be used as follows.
This unit can charge or power Sony devices (video cameras etc.) using a 
 
USB cable compatible with your device. (USB AC adaptor function)
This unit can be used as a charger for Sony “InfoLITHIUM” battery 
 
packs (V series/H series/P series/W series/M series). (Battery charger 
function)
Operation mode of this unit
The USB AC adaptor function and battery charger function can be used 
 
at the same time. (Simultaneous charge mode)
You can make this unit charge a battery pack quicker than usual by 
 
pressing the quick charge button. (Quick charge mode)
Operation 
mode
Battery 
charging
USB output
Quick charge 
button
Simultaneous 
charge mode
Normal 
charging
Enabled
Off
Quick charge 
mode
Quick charging Disabled
On
“InfoLITHIUM” battery packs (V series/H series/P series/W series/M 
series) have the 
/
/
/
/
 
mark.
“InfoLITHIUM” is a trademark of Sony Corporation.
This unit cannot be used to charge a nickel cadmium battery pack or 
 
nickel metal hydride battery pack.
This unit can be only be used to charge “InfoLITHIUM” battery 
 
packs (V series/H series/P series/W series/M series).
 Identifying the parts
Charging status indicator lamp
CHARGE lamp
Quick charge button
USB connector
Power plug
Battery terminal (for M series)
Battery terminal (for V/H/P series)
Battery terminal (for W series)
 mark (for M/V/H/P series)
10   mark (for W series)
To Charge the Battery Pack
The battery pack is charged by attaching it to this unit.
1  Attach the battery pack.
InfoLITHIUM V/H/P series (See illustration 
)
InfoLITHIUM M series (See illustration 
 Align the  mark on the battery pack in the direction of the  
mark on this unit and insert it. 
 Slide the battery pack in the direction illustrated.
InfoLITHIUM W series (See illustration 
)
 Align the  mark on the battery pack in the direction of the  
mark on this unit, and bring the battery pack into contact with the 
battery terminal (for W series) of this unit.
 Press the battery pack in the direction illustrated until it is flat 
inside this unit.
2  Lift the power plug and connect it to a wall outlet (wall 
socket).
Always connect the power plug with the prongs at the top. (See 
illustration 
)
Do not connect the power plug with the prongs at the bottom. (See 
illustration 
)
The CHARGE lamp (orange) lights up and charging begins.
The CHARGE lamp goes out when the battery pack is about 90 % 
charged.
The charging status indicator lamp goes out when charging is 
completed. (Full charge)
Notes
Do not lift this unit by the battery pack.
 
Be careful not to hit the battery pack against this unit.
 
Be careful not to catch your fingers when attaching and removing 
 
the battery pack.
To remove the battery pack
InfoLITHIUM V/H/P series
InfoLITHIUM M series
Remove the battery pack by sliding it in the opposite direction to when 
you attached it.
InfoLITHIUM W series
Lift the battery pack up and remove it.
You can check the approximate charging status with the charging status 
indicator lamp.
 
 ... Off,   
 ... Lit up
Charging status 
indicator lamp
CHARGE lamp
Immediately after 
attaching the battery 
pack - 30 %
30 % - 60 %
60 % - 90 %
90 % - Full charge
Full charge 
completed
The charge level shown by the charging status indicator lamp and the 
percentages in the above table are rough guides.
The actual status may differ depending on the ambient temperature or the 
condition of the battery pack.
Charging time
The following table shows the charging time for a battery pack that is 
completely discharged.
Battery pack
NP-FH50
NP-FV50
NP-FV70
NP-FV100
Full charge 
time
170
195
400
750
Battery pack
NP-FW50
NP-FM500H
NP-FM50
NP-QM71D NP-QM91D
Full charge 
time
145
270
205
395
620
Approximate number of minutes to charge an empty battery pack.
 
For more about the battery life, see the instruction manual of your 
 
device.
The charging time may differ depending on the condition of the battery 
 
pack or the ambient temperature.
The times shown are for charging an empty battery pack which has 
 
been run down with a device, using this unit at an ambient temperature 
of 25 °C (77 °F).
Charging temperature
The temperature range for charging is 0 °C to 40 °C (32 °F to 104 °F).  
For maximum battery efficiency, the recommended temperature 
range when charging is 10 °C to 30 °C (50 °F to 86 °F).
Notes
If the CHARGE lamp does not light up, check if the battery pack is 
 
firmly attached to this unit.
When a fully charged battery pack is installed, the CHARGE lamp 
 
lights up once and then goes out.
A battery pack that has not been used for a long time may take longer 
 
than usual to charge.
Thank you for purchasing the Sony Battery charger.
Before operating this Battery charger, please read this manual thoroughly 
and retain it for future reference.
Owner’s Record
The model and serial numbers are located on the bottom. Record the 
serial number in the space provided below. Refer to these numbers 
whenever you call upon your Sony dealer regarding this product.
Model No. BC-QM1 
Serial No.  
The nameplate indicating operating voltage, power consumption, etc. is 
located on the bottom.
WARNING
To reduce the risk of fire or electric shock,
1) do not expose the unit to rain or moisture.
2) do not place objects filled with liquids, such as vases, on the apparatus.
NOTICE FOR THE CUSTOMERS IN THE U.S.A. AND CANADA
IMPORTANT SAFETY 
INSTRUCTIONS
SAVE THESE INSTRUCTIONS.
DANGER - TO REDUCE THE RISK 
OF FIRE OR ELECTRIC SHOCK, 
CAREFULLY FOLLOW THESE 
INSTRUCTIONS.
This power unit is intended to be correctly orientated in a vertical or 
floor mount position.
For connection to a supply not in the U.S.A., use an attachment plug 
adapter of the proper configuration for the power outlet.
CAUTION
Do not use this unit in a narrow space such as between a wall and 
 
furniture.
Use the nearby wall outlet (wall socket) when using this unit. 
 
Even when the CHARGE lamp of this unit is off, the power is not 
disconnected. If any trouble occurs while this unit is in use, unplug it 
from the wall outlet (wall socket) to disconnect the power.
The set is not disconnected from the AC power source (mains) as long 
as it is connected to the wall outlet (wall socket), even if the set itself has 
been turned off.
Do not expose the batteries to excessive heat such as sunshine, fire or the 
like.
NOTICE FOR THE CUSTOMERS IN THE U.S.A. 
CAUTION
You are cautioned that any changes or modifications not expressly 
approved in this manual could void your authority to operate this 
equipment.
NOTE
This equipment has been tested and found to comply with the limits for 
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio 
communications.  
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
 
Increase the separation between the equipment and receiver.
 
Connect the equipment into an outlet on a circuit different from that to 
 
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
 
Battery to be recharged for this product is follows
Brand Name
Sony
Battery Type
NP-FV30
NP-FV50
NP-FV70
NP-FV100
NP-FH50
Rating 
(Minimum  
Capacity)
DC 7.2V  
3.6 Wh  
(500 mAh)
DC 6.8V  
6.6 Wh  
(980 mAh)
DC 6.8V  
13.0 Wh  
(1,960 mAh)
DC 6.8V  
25.0 Wh  
(3,700 mAh)
DC 6.8 V  
5.9 Wh  
(870 mAh)
Brand Name
Sony
Battery Type
NP-FW50
NP-
FM500H
NP-FM50
NP-QM71D NP-QM91D
Rating 
(Minimum 
Capacity)
DC 7.2V 
7.3 Wh 
(1,020 mAh)
DC 7.2V 
11.5 Wh 
(1,600 mAh)
DC 7.2 V 
7.9 Wh 
(1,100 mAh)
DC 7.2 V 
19.0 Wh 
(2,600 mAh)
DC 7.2V 
33.0 Wh 
(4,500 mAh)
Notes on Use
This unit does not have dust-proof, splash-proof or water-proof 
specifications.
Warranty for Recorded Content
Contents of the recording cannot be compensated if recording or 
playback is not made due to a malfunction of this unit.
Where not to place this unit
Do not place this unit in any of the following locations, whether it is in 
use or in storage. Doing so may lead to a malfunction.
In direct sunlight such as on dashboards or near heating apparatus, as 
 
this unit may become deformed or malfunction
Where there is excessive vibration
 
Where there is strong electromagnetism or radiant rays
 
Where there is excessive sand 
 
In locations such as the seashore and other sandy areas or where dust 
clouds occur, protect this unit from sand and dust. There is a risk of 
malfunction.
Precautions on Use
Connect this unit to an available wall outlet (wall socket). Even when 
 
the CHARGE lamp of this unit is off, the power is not disconnected. 
If any trouble occurs while this unit is in use, unplug it from the wall 
outlet (wall socket) to disconnect the power.
Do not use this unit in a narrow space such as between a wall and 
 
furniture.
Attach the battery pack firmly to this unit when charging the battery 
 
pack.
The battery terminal may be damaged if the battery pack is not attached 
 
correctly.
To protect the battery pack, remove it from this unit when charging is 
 
completed.
Do not drop or apply mechanical shock to this unit.
 
Keep this unit away from TVs or AM receivers. 
 
Noise from this unit may enter a TV or radio if placed nearby.
Unplug this unit from the wall outlet (wall socket) after use.
 
Be sure that nothing metallic comes into contact with the metal parts of 
 
this unit. If it does, a short may occur and this unit may be damaged.
The battery pack and this unit can become warm during or 
 
immediately after recharging.
The USB connector of this unit is for output only. Do not connect it to 
 
the USB port of a computer, etc. Doing so may cause a malfunction.
Some USB rechargeable devices cannot be used with this unit. Also, 
 
some devices may not be operable while recharging. Check the charging 
specifications in the instruction manual of your device.
When you use the USB connector of this unit, attach a battery pack to 
 
the connected device. Not doing so may cause data loss from the device 
or damage due to the device crashing.
Be warned that some devices may suddenly lose their input memory 
 
regardless of whether they are used with the USB connector of this unit. 
(For details, refer to the instruction manual supplied with your device.) 
Always back up the input memory beforehand. Sony is not liable for 
any loss of input memory when using this unit.
Make sure before using this unit that its current and voltage match 
 
those of the outlet. 
Depending on the conditions of use of this unit’s USB connector, this 
 
unit may automatically shut down for safety reasons if the input current 
is too high.
Sony does not guarantee operation of this unit if you use it with a USB 
 
hub or USB extension cable. Always follow the designated connecting 
method of the USB cable supplied with your device.
Use this unit with the USB cable (See 
illustration 
)
1  Connect your device to this unit.
2
  Lift the power plug up and connect it to a wall outlet (wall 
socket).
Powering starts automatically.
Powering does not start if the quick charge button is lit. Press the 
quick charge button to turn it off before using this unit.
3  After the device is completely recharged, unplug this unit 
and disconnect the device from this unit.
Notes
A USB cable is not supplied with this unit. Prepare a USB cable 
 
compatible with your device.
You may need to perform some operation on your device to use the 
 
USB AC adaptor function of this unit. The operation and specifications 
differ depending on your device model. For details, refer to the 
instruction manuals of your device.
Connecting this unit to a device via 
USB cable while still charging the 
battery pack (Simultaneous charge 
mode)
This unit can charge a battery pack and power a device connected via 
USB cable at the same time.
For details on attaching a battery pack to this unit, see “To Charge the 
Battery Pack.”
For details on connecting to a device, see “Use this unit with the USB 
cable.”
Charging in a shorter time (Quick 
charge mode)
During battery pack charging, press the quick charge button to charge in 
a shorter time.
The quick charge button lights up orange during quick charge mode.
Notes
“Simultaneous charge mode” and “Quick charge mode” cannot be used 
 
at the same time. 
When quick charge is started, powering to a device connected via USB 
cable stops. 
Always check the status of your device before use. 
When quick charge is completed, powering to the device connected via 
USB cable restarts.
This unit will not switch to quick charge mode if no battery pack is 
 
attached. Always attach a battery pack to this unit before operating the 
quick charge button.
Charging time in quick charge mode
Battery pack
NP-FH50
NP-FV50
NP-FV70
NP-FV100
Full charge 
time
70
80
125
230
Battery pack
NP-FW50
NP-FM500H
NP-FM50
NP-QM71D NP-QM91D
Full charge 
time
115
160
140
225
330
Approximate number of minutes to charge an empty battery pack.
 
The charging time may differ depending on the condition of the battery 
 
pack or the ambient temperature.
The times shown are for charging an empty battery pack which has 
 
been run down with a device, using this unit at an ambient temperature 
of 25 °C (77 °F).
This unit supports worldwide voltages 100 V to 240 V.
Do not use an electronic voltage transformer, as this may cause a 
malfunction.
The shape of wall outlets (wall sockets) differs depending on the 
country and region. Check before departure.
Troubleshooting
When the CHARGE lamp blinks, check through the following chart.
The CHARGE lamp blinks in two ways.
Blinks slowly:  Turns on and off repeatedly every 1.5 seconds
Blinks quickly: Turns on and off repeatedly every 0.15 seconds
The action to be taken depends on the way the CHARGE lamp blinks.
When the CHARGE lamp keeps blinking slowly
Charging is pausing. This unit is in the standby state.
If the room temperature is out of the appropriate temperature range, 
charging stops automatically.
When the room temperature returns to the appropriate range, the 
CHARGE lamp lights up and charging restarts.
We recommend charging the battery pack at 10 °C to 30 °C (50 °F to  
86 °F).
When the CHARGE lamp keeps blinking quickly
When charging the battery pack for the first time in one of the 
following situations, the CHARGE lamp may blink quickly. 
If this happens, remove the battery pack from this unit, reattach it and 
charge it again.
 When the battery pack is left for a long time
 When the battery pack is left installed in the camera for a long time
 Immediately after purchase
If the CHARGE lamp keeps blinking quickly, check through the following 
chart.
Please contact your nearest Sony dealer in connection with the product that may 
have a problem.
Remove the battery pack that is being charged and then firmly attach the same 
battery pack again.
The CHARGE lamp blinks again:
Install another battery pack.
The CHARGE lamp lights up and 
does not blink again:
If the CHARGE lamp goes out 
because the charging time has 
passed,  there is no problem.
The CHARGE lamp blinks again:
The problem is with this unit.
The CHARGE lamp lights up and 
does not blink again:
If the CHARGE lamp goes out 
because the charging time has 
passed,  the problem is with the 
battery pack first installed.
The battery pack cannot be charged.
This unit is not connected to the wall outlet (wall socket).
 
Connect this unit to the wall outlet (wall socket) properly.
 
The battery pack is not firmly attached.
 
Attach the battery pack to this unit correctly.
 
The device connected by the USB cable does not work.
This unit is not connected to the wall outlet (wall socket).
 
Connect this unit to the wall outlet (wall socket) properly.
 
The device connected to this unit may need to be operated.
 
Refer to the instruction manual of the connected device.
 
This unit is set to quick charge mode.
 
When this unit is set to quick charge mode, powering the device 
 
connected with a USB cable is stopped. 
Operate the quick charge button and check that its light is off.
Specifications
Input rating
100 V - 240 V AC   50 Hz/60 Hz 
0.38 A
Output rating
8.4 V DC   1,600 mA (BATTERY CHARGE)
5.0 V DC  1,500 mA (USB POWER 5V 1500mA)
Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Dimensions (Approx.) 67 mm × 49 mm × 105 mm (w/h/d) 
(2 3/4 in. × 1 15/16 in. × 4 1/4 in.) 
Mass
Approx. 175 g (6.2 oz)
Included items
Battery Charger (BC-QM1) (1)
Set of printed documentation
Design and specifications are subject to change without notice.
2