Shenyang Torch-Bigtide Digital Technology Co. Ltd. 19LCD1928M User Manual

Page of 20
Last change:   
2012-3-1
 
User Manual 
HL1928M-L/R 
Page 17 of 
32
 
 
 
Fine adjustment of the flat panel display   
Note   
Fine adjustment of the flat panel display can only be carried out via the analog 
port.  The  digital  input  (DVI-D,)  does  not  require  a  fine  adjustment  since  the 
display signal is always optimum. 
RGB  picture  sources  via  VGA  connector  supply  analog  signals  which  are 
basically  intended  for  conventional  CRT  monitors  and  which  are  processed 
directly by them.   
In  contrast,  the  analog  signals  must  be  converted  for  a  flat  panel  display  into 
digital signals by a video digitizer. Depending on the picture source, cable length 
and  video  mode  (e.g.  VGA,  SVGA,  XGA)  this  conversion  may  cause  certain 
deviations which cannot be corrected fully automatically by the flat panel display. 
A  manual  fine  adjustment  is  therefore  necessary  during  which  the  flat  panel 
display  (or,  more  precisely,  the  video  digitizer)  is  matched  to  the  respective 
video source. The fine adjustment comprises e.g. setting the horizontal/vertical 
picture position  and the picture  sharpness. This can be  carried  out for the flat 
panel display HL1928M using an OSD menu.   
To optimize the display settings for the installed graphic board, and to ensure all 
gray  levels  are  distinguishable,  we  recommend  to  adjust  the  brightness  and 
contrast  levels  for  and  only  for  analog  inputs.  Note  that  the  calibration  (in  the 
Look Up Table) is not changed by these adjustments (All the monitors are and 
remain factory calibrated):   
Using  a  100%  black  picture  and  an  appropriate  measurement  device  (a  spot 
meter  recommended),  decrease  the  brightness  level  using  the  OSD  controls 
until the measurement device displays a constant level (i.e. the measured value 
no longer changes). Once this is achieved, increase the brightness level slightly 
until  the  display  is  just  above  the  absolute  lowest  black  level  (one  step  is 
generally sufficient).   
Similarly,  set  the  white  level  using  a  100%-white  test  pattern  and  the 
measurement device. Only the contrast level should be adjusted to ensure that 
the black level remains unchanged.   
Control  again  the  black  value  did  not  change.  In  case  it  did  you  need  to 
duplicate  the  two  previous  steps  until  it  does  not  change  anymore  (cause: 
pedestal).   
Increase the contrast level until the measurement device no longer detects an 
increase  in  luminance.  Once  this  is  achieved,  decrease  the  contrast  level