H&D Wireless AB BOX860 User Manual

Page of 18
Data Sheet  
1451- Data Sheet    
BOX860 
 
 
Rev. A Dec-2015 
Data Sheet 1451-BOX860 
                         page  7 (18) 
Confidential 
 
3  ELECTRICAL DATA 
3.1  Absolute maximum ratings 
 
Rating 
Min 
Max 
Unit 
Supply voltage  
-0.3 
4.5 
Input RF level  
 
10 
dBm 
Storage temperature 
+50 
o
Table 3.1: Absolute maximum ratings. Exceeding any of the maximum ratings, even briefly lead to deterioration in 
performance or even destruction. Values indicates condition applied one at the time. 
3.2  Electro Static Discharge (ESD) 
BOX860 withstands ESD voltages up to 2000V HBM (Human Body Model) according to JESD22-A114 and up 
to 300 V CDV (Charged Device Model) according to JESD22-A115. 
 
3.3  Recommended operating conditions 
 
Symbol 
 
Min 
Typ. 
Max 
Unit 
VCC 
Supply Voltage 
3.0 
 
4.5 
T
OP
 
Operating temperature 
 
50 
o
C
 
 
Indoor use or corresponding 
temperature and humidity conditions 
 
 
 
 
Table 3.2: Recommended operating conditions 
3.4  Power Consumption 
If no other conditions are started does VDD=3.6V, T
amb
 = 25
o
C apply.  
Mode 
Conditions 
Min 
Typ. 
Max 
Unit 
Peak current 
All modes 
 
 
300 
mA 
TX [802.11b] 
CCK 11Mbps 
 
205 
230 
mA 
TX [802.11g] 
OFDM 54 Mbps 
 
165 
200 
mA 
TX [802.11n] 
OFDM 65 Mbps 
 
140 
170 
mA 
RX [802.11b] 
Max sensitivity 
 
53 
59 
mA 
RX [802.11g] 
Max sensitivity 
 
56 
64 
mA 
RX [802.11n] 
Max sensitivity 
 
56 
64 
mA 
Record 
WiFi Associated 
 
58 
 
mA 
Playback 
WiFi Associated 
 
70 
 
mA 
Idle 
Between check for 
messages 
 
0.2 
 
mA